Refrigerant System Diagram; Troubleshooting - Mitsubishi Electric PKFY-P15VBM-E Technical & Service Manual

Split-type, heat pump air conditioners series pkfy wall mounted r410a/r407c/r22
Hide thumbs Also See for PKFY-P15VBM-E:
Table of Contents

Advertisement

7

REFRIGERANT SYSTEM DIAGRAM

PKFY-P15, 20, 25VBM-E
PKFY-P20, 25VBM-ER1
PKFY-P15, 20, 25VBM-ER2
8

TROUBLESHOOTING

8-1. HOW TO CHECK THE PARTS
PKFY-P15, 20, 25VBM-E
PKFY-P20, 25VBM-ER1
PKFY-P15, 20, 25VBM-ER2
Parts name
Disconnect the connector then measure the resistance with a tester.
(At the ambient temperature 10 ~30 )
Liquid pipe temperature
thermistor (TH22)
Gas pipe temperature
thermistor (TH23)
Vane motor (MV)
Measure the resistance between the terminals with a tester. (At the ambient temperature 25 )
4
M
Pink or
2
Red-Pink or White
1
Red
Yellow Blue
Connect pin No.
5
3
Fan motor (MF)
Measure the resistance between the terminals with a tester. (At the ambient temperature 20 )
FAN
1
White
4
Black
6
Linear expansion
Disconnect the connector then measure the resistance valve with a tester.
valve (LEV)
(Coil temperature 20 )
CN60
White
1
2
Orange
3
LEV
Blue
White-Red
4
Red
5
6
OCH418B
Heat exchanger
Room temperature thermistor
TH21
Service ref.
Item
Gas pipe
Normal
Abnormal
4.3k ~9.6k
Open or short
Normal
Normal
-
-
Red-Blue
Red-Orange
400 7%
Normal
White-Black
286
Red-Black
200
Normal
(1)-(5)
(2)-(6)
Yellow-Brown
Orange-Red
150 10%
Gas pipe temperature thermistor
TH23
Liquid pipe temperature thermistor
TH22
Strainer
(#100mesh)
{12.7 (1/2")
{6.35 (1/4")
Refer to the next page for the details.
-
-
Red-Yellow
Open or short
Abnormal
Open or short
(3)-(5)
(4)-(6)
Blue-Brown
Open or short
14
Gas pipe
Strainer
(#100mesh)
Liquid pipe
Linear expansion
valve
Strainer
(#100mesh)
Unit: mm(inch)
Abnormal
Abnormal
Flare