Download Print this page

Advertisement

Available languages

Available languages

Quick Links

Thermozone AD Corinte A/E - ADCS
SE
GB
RU
.... 23
.... 26
.... 29

Advertisement

loading

Summary of Contents for Frico Thermozone AD Corinte A/E

  • Page 1 Thermozone AD Corinte A/E - ADCS ..23 ..26 ..29...
  • Page 2 Thermozone AD Corinte A/E - ADCS...
  • Page 3 Thermozone AD Corinte A/E - ADCS...
  • Page 4 Thermozone AD Corinte A/E - ADCS...
  • Page 5 Thermozone AD Corinte A/E - ADCS Fig 4...
  • Page 6 Thermozone AD Corinte A/E - ADCS Fig 5 Fig 7 Fig 6...
  • Page 7 Thermozone AD Corinte A/E - ADCS 1700/2200 1670/2170 Wall Left connection Right connection Ø30 Fig 8 Ø20 (3x) ADCS A/E: Min 220 mm ADCS A/E: Min 220 mm ADCS W: Min 180 mm ADCS W: Min 180 mm Fig 9...
  • Page 8 Thermozone AD Corinte A/E - ADCS SIRe Fig 10...
  • Page 9 Thermozone AD Corinte A/E - ADCS ADCEH Ø8 2 alternatives for securing at the top. Ø12 (2x) Ø8 for securing at the air curtain.
  • Page 10 Thermozone AD Corinte A/E - ADCS Regulations alternatives This aircurtain is supplied with an intelligent pre-programmed with quick-release connec- and well designed low voltage control system tions and is very easy to use and install. There SIRe which can be customized for each uni- are three different levels with different fun- que application and environment.
  • Page 11: Wiring Diagrams

    Thermozone AD Corinte A/E - ADCS Wiring diagrams Internal ADCS A ADCSA 230V~ Internal Motor sensor protection 230V Yellow 230V 200V Orange 200V 170V 170V 145V Brown 145V 120V Black 120V 100V Green 100V Blue Blue Black...
  • Page 12 Thermozone AD Corinte A/E - ADCS Wiring diagrams AD Corinte A Ambient control options SIRe Basic SIReB1 SIReUB1 SIRe Basic - Parallel connection SIReB1 SIReB1 SIReUB1...
  • Page 13 Thermozone AD Corinte A/E - ADCS Wiring diagrams AD Corinte A Ambient control options SIReAC Competent ˚C ˚C ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP.
  • Page 14 Thermozone AD Corinte A/E - ADCS SIReAC Competent - Parallel connection ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP. ON/OFF (potential free contact)
  • Page 15 Thermozone AD Corinte A/E - ADCS Wiring diagrams Internal ADCS E 400 V3~ ADCSE 400V3~ 400V3~ 230V~ Internal Motor sensor protection 230V Yellow 230V 200V Orange 200V 170V 170V 145V Brown 145V 120V Black 120V 100V Green 100V Blue Blue...
  • Page 16 Thermozone AD Corinte A/E - ADCS Wiring diagrams Internal ADCS E 230 V3~ ADCSE 230V3~ L1L2 230V3~ 230V~ Internal Motor sensor protection 230V Yellow 230V 200V Orange 200V 170V 170V 145V Brown 145V 120V Black 120V 100V Green 100V Blue...
  • Page 17 Thermozone AD Corinte A/E - ADCS Wiring diagrams AD Corinte E Electrical control options SIRe Basic SIReB1 SIReRTX SIReUB1 230V~ (optional) SIRe Basic - Parallel connection SIReB1 SIReB1 SIReUB1 SIReRTX 230V~ 230V~ (optional)
  • Page 18 Thermozone AD Corinte A/E - ADCS Wiring diagrams AD Corinte E Electrical control options SIReAC Competent ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP.
  • Page 19 Thermozone AD Corinte A/E - ADCS SIReAC Competent - Parallel connection ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP. ON/OFF (potential free contact)
  • Page 20 Thermozone AD Corinte A/E - ADCS Wiring diagrams AD Corinte E Electrical control options SIReAA Advanced BMS INDICATION OUT (potential free contact max 3A, 230V) ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL HEAT 0-10V DC IN...
  • Page 21 Thermozone AD Corinte A/E - ADCS SIReAA Advanced - Parallel connection BMS INDICATION OUT (potential free contact max 3A, 230V) ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL HEAT 0-10V DC IN EXTERNAL RPM 0-10V DC IN...
  • Page 22 Thermozone AD Corinte A/E - ADCS Technical specifications | Thermozone AD Corinte A without heat 1 Type Output Airflow Sound Output Voltage Amper- Length Weight level* motor motor [kW] [dB(A)] motor [mm] [kg] ADCS17A*¹ 1400/3000 40/60 230V~ 1700 ADCS22A 1800/4000...
  • Page 23 Spara manualen 1. Lossa skruvarna i frontplåten. för framtida bruk. 2. Lossa skruvarna som fäster frontplåten i Garantin gäller endast om Frico montage- utblåsgallret. och bruksanvisning har följts och aggregaten 3-4. Plocka bort frontplåten. använts såsom däri är beskrivet.
  • Page 24 Thermozone AD Corinte A/E - ADCS na vid montering (medlevereras). (Generellt kan sägas att ju större belastning, 3. Lyft apparaten på plats och fäst konsolerna desto större vinkel krävs.) i pendlarna. Lossa, med hjälp av insexnyckel, de tre Observera! Apparaten kan ej pendlas i kedjor skruvarna som håller utblåsgallret.
  • Page 25 Thermozone AD Corinte A/E annat underhåll än rengöring vid behov, dock Säkerhet minst två gånger per år. • Vid alla installationer av elvärmda produk- En provflaska ”Fingerprint remover” med- ter bör jordfelsbrytare 300 mA för brand- levereras, produkten lämnar en ren och torr skydd användas.
  • Page 26 Thermozone AD Corinte A/E - ADCS Assembly and operating instructions curtain. The ventilation should therefore be General instructions balanced. Read these instructions carefully before in- stallation and use. Keep this manual for future Vertical mounting reference. The unit is mounted vertically on the floor The guarantee is only valid if the Thermo- with the exhaust opening facing outwards.
  • Page 27 Thermozone AD Corinte A/E - ADCS Horizontal mounting on the wall quick-release connections. 1. Mount the brackets on the wall according to Modular cables are connected to the con- measurements in Fig. 7 and 8. trol board Base, by opening the front plate, as 2.
  • Page 28 Thermozone AD Corinte A/E - ADCS Safety 2 That the heat demand exists; check thermostat settings and actual temperature. • For all installations of electrically heated products should a residual current circuit 3 That the output selector (if any) is set correctly.
  • Page 29: Принцип Действия

    Thermozone AD Corinte A/E Инструкция по монтажу и эксплуатации Thermozone AD Corinte A/E Вертикальная установка Общие положения Завесы устанавливаются вертикально, с Внимательно изучите настоящую инструкцию направлением каналов выдува в сторону до начала монтажа и эксплуатации. защищаемого проема. Сохраните данную инструкцию для...
  • Page 30 каждый болт (поставляется в комплекте с сечение 1.5 мм2. Если длина кабеля больше завесой). – проконсультируйтесь со специалистами 3. Поднимите завесу к месту установки и Frico. соедините и закрепите скобы и стержни Внимание! Перед тем как установить подвески. переднюю панель, убедитесь, что вентилятор...
  • Page 31 Thermozone AD Corinte A/E после чего затяните винты. Обслуживание Перегрев Внимание! Отключите центральный Электродвигатели всех завес оборудованы выключатель завесы на распределительном термо датчиками, защищающими защиты щите до проведения обследования или завесы от перегрева. Смотри схему чистки завесы (в воздушных завесах...
  • Page 32 Thermozone AD Corinte E - ADCS Безопасность • Пространство вблизи решеток забора, выдува воздуха не должно загромождаться какими-либо предметами или материалами! • Будьте осторожны, при работе поверхности прибора нагреваются! • По избежание перегрева прибора и появления пожарной опасности он не должен покрываться какими-либо предметами...
  • Page 36 Main offi ce Frico AB Tel: +46 31 336 86 00 Fax: +46 31 26 28 25 Box 102 SE-433 22 Partille Sweden...