Advertisement

Quick Links

Original instructions
PAEC4000
EN
FR
.... 21
.... 26
Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance
with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of
the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to airflow rate,
average outlet velocity, outlet velocity uniformity, velocity projection and power rating at free
delivery only.

Advertisement

Table of Contents
loading

Summary of Contents for Frico PAEC4000W

  • Page 1 ..21 ..26 Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
  • Page 2 12.86 11.5 Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
  • Page 3: Imperial Chart

    2531 2263 Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
  • Page 4: Metric Chart

    PAEC4000 Output charts water PAEC4000 Metric chart Supply water temperature:80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water flow drop air temp.
  • Page 5 PAEC4000 The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Les pages de présentation contiennent principalement des images. Pour la traduction des textes en anglais, consultez la page correspondante à la langue souhaitée.
  • Page 6 PAEC4000 PAEC4000 DN20 (3/4"), outside thread A / B / C / D PAEC 2; 2.5 m / 6.6; 8.2 ft E / F Ref Metric Imperial Product type [mm] [in] 1039 41.56 PAEC4010x 1549 61.96 PAEC4015x 2039 81.56 PAEC4020x 2549 101.96 PAEC4025x...
  • Page 7 PAEC4000 Fig. 1A: Open the unit by raising the front panel. Fig. 1B: When the front has been removed it it The front is blocked in open position with the important to be sure it is firmly seated in the front front hatch hook.
  • Page 8 PAEC4000 PAEC4010x/PAEC4015x D / E Metric Imperial Product type [mm] [in] 5.08 PAEC4010/15/20/25x 4.08 PAEC4010/15/20/25x 9.40 PAEC4010/15/20/25x 30.00 PAEC4010x 1260 50.40 PAEC4015x 35.00 PAEC4020x 29.80 PAEC4025x 30.80 PAEC4025x PAEC4020x PAEC4025x Fig. 5: M8-holes for mounting.
  • Page 9 PAEC4000 PAEC4000 + PA34WB/PAWBL PA34WB/ PAWBL 20 mm / 0,80" 20 mm PA34WB Metric Imperial [mm] [in] 0.43 0.75 3.15 1.58 1.58 4.72 PAWBL Metric Imperial [mm] [in] 0.43 0.75 4.72 2.36 52.5 2.07 6.50 Type Product type Quantity Length Length Fig.
  • Page 10 PAEC4000 Accessories PA34CB PA34TR PA34WS (PA34VD) (PA34CB) Fig. 7: PA34TR + PA34CB + PA34VD. Fig.8: PA34WS + PA34CB See separate manual for PA34TR. See separate manual for PA34WS. Type Product type Quantity Length Length included Metric Imperial PA34CB15 PAEC4010/15x 4 pcs PA34CB20 PAEC4020x 6 pcs...
  • Page 11 PAEC4000 Accessories Type Product type Length Length Metric Imperial [mm] [in] PA4XT10 PAEC4010x 130-200 5.20-8.00 PA4XT15 PAEC4015x 130-200 5.20-8.00 PA4XT20 PAEC4020x 130-200 5.20-8.00 PA4XT25 PAEC4025x 130-200 5.20-8.00 Fig. 10: See separate manual for PA4XT. Type Product type Dimensions Dimensions PA4DW Metric Imperial [mm]...
  • Page 12 PAEC4000 Accessories Note! The air curtain must be secured in the wall or ceiling. PA4VDW PA4JK Fig. 11: See separate manual for PA4JK.
  • Page 13 AXP300 PAEC4000 See separate manual for DTV200S See separate manual for PA34EF. FHDN20. Type Product type Length Length Metric Imperial PA34EF10 PAEC4010W PA34EF15 PAEC4025W PA34EF20 PAEC4020W PA34EF25 PAEC4025W DTV200S PAEC4000W FHDN20 PAEC4000W 350 mm 13.8 in FHDN2010 PAEC4000W 3.3 ft...
  • Page 14 PAEC4000 Accessories SIReACY SIReRTX SIReUR SIReWTA SIReCJ4/SIReCJ6 SIReCC SIReAAY Type Dimensions Length Dimensions Length Metric Metric Imperial Imperial SIReACY SIReAAY SIReRTX 70x33x23 mm 2.80x1.32x0.92 in SIReUR 114x70x50 mm 4.56x2.80x2.00 in SIReWTA SIReCJ4 SIReCJ6 SIReCC603 9.8 ft SIReCC605 16.4 ft SIReCC610 10 m 32.8 ft SIReCC615...
  • Page 15 PAEC4000 PAEC4000A/W 4025WA/4020WA/4015WA 4010WA SIRe B1EC Trafo AREC4000W/A PAEC4000W/A 161120 PE L1 L2 208V1~...
  • Page 16 PAEC4000 PAEC4010/15E-208V Actuator 230V Supply 230V Room...
  • Page 17 PAEC4000 PAEC4020/25E-208V Actuator 230V Supply 2 30V Room...
  • Page 18 PAEC4000 PAEC4010/15E-480V/600V A ctuato r 230V S upply 230V R oom...
  • Page 19 PAEC4000 PAEC4020/25E-480V/600V Actuator 230V Supply 230V Room...
  • Page 20 PAEC4000 • Read the safety instructions before performing installation and/or maintenance activities on the unit. • Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. • The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
  • Page 21: General Instructions

    PAEC4000 Installation and operating instructions General Instructions Mounting Read these instructions carefully prior to The air curtain range can be adapted for installation and use. Keep this manual for vertical or horizontal installation. The units can future reference. also be installed by recessing into suspended The product may only be used as set out in ceilings.
  • Page 22: Electrical Installation

    PAEC4000 Vertical mounting PA4JK Units from 1.5 metres/4.9 feet and longer may Unit with electrical heating be used vertically. For vertical mounting, all The electrical connection is made on the top units must be supplemented with a vertical kit of the unit. See Fig.2. 208V3~/480V3~/600V3~ containing everything needed for a practical power supply for heat and control (*1 *2) installation of floor standing units.
  • Page 23: Maintenance

    1B. The service hatch is The connections to the heating coil must be removed by loosening the screws. equipped with shut off valves (included in Frico 3. After service, repairs and maintenance fasten valve kits) to allow problem free removal.
  • Page 24: Troubleshooting

    PAEC4000 Overheating Troubleshooting The air curtain unit with electrical heating is If the fans are not working or do not blow properly, equipped with an overheat protection. If it is check the following: • That the intake grille/filter is not dirty. deployed due to overheating, reset as follows: •...
  • Page 25 PAEC4000 Packaging Safety Packaging materials are chosen with • For all installations of electrically heated consideration to the environment and are products a residual current circuit breaker therefore recyclable. 300 mA for fire protection should be used. • Keep the areas around the air intake and Handling of product at end of working exhaust grilles free from possible obstructions! life...
  • Page 29 Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net.

Table of Contents