HOST CONFIGURATION STRINGS
DESCRIPTION
Field Adjustment
Field Adjustment Character
Character Replacement
Address Stamping
Address Delimiter
Time Stamping
Time Stamping Delimiter
e, f, g h = HEX values representing an ASCII character
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 65.
d = a number in the range 01-32 from the Hex/Numeric Table
e = Hex value from 00 to FE
f = Hex value of the character to be replaced from 00 to FE
g = Hex value of the new character to insert from 00 to FE
FF = replace with no new character (remove character)
h = a HEX value in the range from 00 - FE representing the ASCII character.
DATA FORMAT (continued)
NOT FOR PEN EMULATION INTERFACES
Disable
right addition
left addition
right deletion
left deletion
disable character replacement
first character replacement
second character replacement
third character replacement
disable reader address stamping
enable reader address stamping
disable cradle address stamping
enable cradle address stamping
disable reader address delimiter
enable reader address delimiter and select
character
disable cradle address delimiter
enable cradle address delimiter and select
character
Disable
hour/minutes/seconds/month/day/year
hour/minutes/seconds/day/month/year
hour/minutes/seconds
month/day/year
day/month/year
disable time stamping delimiter
enable time stamping delimiter and select
character
a = ASCII character.
d = a number from the Hex/Numeric Table
A
STRING
EF0
EF a 0 d
EF a 1 d
EF a 2 d
EF a 3 d
EG e
EO0
EO1 afg
EO2 afg
EO3 afg
RU0
RU1
RW0
RW1
RV0
RV1 h
RY0
RY1 h
IL0
IL1
IL2
IL3
IL4
IL5
IM0
IM1 h