Excess Flow Safety Valve Reset Procedure - BBQ GSF2616AC Owner's Manual

3 burner cart gas grill
Table of Contents

Advertisement

Confirm that the burner is properly lit and that the flame pattern is as desired (see fig. A,B and C below for the proper flame patterns).
If the flame pattern is other than normal, consult the Troubleshooting on page 16 for corrective action.
FIG. A
Normal: Soft blue flames with yellow tips
between I inch - 2 inches high.
Burner installation and adjustment
1. Eng edge face upside for install the
burner.
WARNING: Adjusting the air-shutter while the
grill is on operation. If it is still hot, please wear protective gear and be careful. Failure to follow this instruction could cause
personal injury.
Flare-ups
"Flare-ups" sometimes occur when food drippings fall onto the hot heat distribution plate or burners and ignite. Some flaring is normal
and desirable as it helps impart the unique flavors associated with grilled foods. Controlling the intensity of the flare-ups is necessary,
however, in order to avoid burned or unevenly cooked foods and to prevent the possibility of accidental fire.
WARNING: Always monitor the grill closely when cooking and turn the flame level down to LOW or OFF if flare-ups
intensify.
Shutting Off Burners
1. Always turn the valve knob(s) clockwise to the ''HIGH'' position, and then press and turn it to ''OFF''. Never force the knob
without pressing it. This could damage the valve.
2.
Promptly turn the gas supply to the "OFF" position at the propane cylinder.
3.
Close the lid of the grill.

Excess flow safety valve reset procedure

The new regulators are equipped with a safety device that restricts the gas flow in the event of a gas leak. However, unsafe
practices of grill operation could activate the safety device without having a gas leak.
A sudden shut off of the gas flow typically occurs if you open the LP tank valve rapidly, or if one or more of the burner control
knobs is in an open position when opening the LP tank valve.
This procedure is effective with all LP Tank sizes as well as Natural Gas. When performing the procedure on a
Natural Gas model, simply substitute "Natural Gas valve" for "LP Tank".
GSF2616AC
Owner's Manual
FIG. B
Out of adjustment: Noisy hard blue
flames – too much air.
1. Release the screw on venturi tube.
2. Adjust the flame by turning the collar on head
of venturi tube from back side of the grill and
do not take apart the venturi tube.
3. Tighten the screw and make certain it is
secured.
14
FIG. C
Poor combustion: Wavy, yellow
flames- too little air.
1. Overlap 14 mm between venturi
tube and nozzle when
assembling.
2. Keep the center line of venturi
tube and nozzle on one line.

Advertisement

Table of Contents
loading

Table of Contents