Installation - Water Supply; Installation - Vent Pipe - Heatrae Sadia SUPREME 150SS Fitting Instructions And User Manual

Hide thumbs Also See for SUPREME 150SS:
Table of Contents

Advertisement

4.0 INSTALLATION - WATER SUPPLY

4.1 Select appropriate push fit connector for chosen entry position:
Bottom entry water -
Rear entry water -
Note: stainless or chromed pipes do NOT provide secure
connections with push fit fittings (use copper pipe at joints).
4.2 Push the connector fully home (28mm engagement) onto the
solenoid valve inlet spigot. To remove a push fit connector the
collar (collet) should be pushed towards the body of the fitting
whilst pulling the connector off the pipe.
4.3 If the inlet pipe run is horizontal and beneath the unit ensure it
does not prevent access to the case screws.
4.4 Connect the inlet pipe to the push fit connector ensuring it is fully
pushed home (28mm engagement). After connection DO NOT
make soldered joints in the pipework close to the heater, as the
heat may damage the connector or the water heater itself.
4.5 A WRAS listed isolating valve should be fitted to the cold supply to
facilitate servicing the heater.
4.6 Push fit connectors are supplied to allow either bottom or rear
entry of services. If a combination of entry points are required an
additional connector will be required as follows:
Bottom inlet, rear vent
Rear inlet, bottom vent

5.0 INSTALLATION - VENT PIPE

5.1 Select appropriate push fit connector for chosen entry position:
Bottom entry vent -
Rear entry vent -
5.2 Push the connector fully home (28mm engagement) onto the vent
pipe connection.
5.3 Connect the vent pipe to the push fit connector ensuring it is
pushed fully home (28mm engagement). Refer to the vent pipe
requirements detailed in IMPORTANT INSTALLATION POINTS.
If a bottom entry vent pipe is used the pipe must terminate below
the unit, in a safe visible position. After connection DO NOT make
soldered joints in the pipework close to the heater, as the heat
may damage the connector or the water heater itself.
15mm x 15mm 90° elbow.
15mm x 15mm straight.
15mm x 15mm elbow
(Heatrae Sadia part no. 95 607 510)
15mm x 15mm straight
(Heatrae Sadia part no. 95 607 509)
15mm x 15mm straight
15mm x 15mm 90° elbow
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Supreme 165ssSupreme 180ss

Table of Contents