3. Mount the Fresh Water Flush Check Valve Assembly vertically in close proximity to the Booster Pump, Fresh
Water Flush Filter Canister, and the Pre-Filter.
4. The Booster Pump is mounted to a flat surface using the 4 supplied #10 x 1 1/4" long Type "A" screws. The
Booster Pump is mounted below water level to assist priming, and in an accessible location to allow access for
maintenance. Mount Booster Pump close to the Inlet Thru Hull/ Sea Cock Valve and the Sea Strainer (if
purchased). If the booster pump is mounted vertically, mount the motor up and pump head down. Do not mount
the pump head above the motor else motor damage will occur if the pump or its fittings should develop a leak.
5. The Optional Plankton Filter is mounted inline between the Booster Pump and the Pre Filter. Allow at least 4
inches (10 cm) of clearance below the bowl for element replacement.
6. The Pre-filter is mounted to a bulkhead using the 4 supplied #10 Type "A" 1" long screws. Allow minimum 4
inches (10 cm) below the bowl for filter element removal. Feed water may spill during filter element replacing.
Therefore, Do Not mount the prefilter above any electrical or electronic component
7. The Optional Charcoal Filter is mounted to a vertical bulkhead using the 4 supplied #10 x 1" long Type "A"
screws.
8. The system is mounted to a flat surface using the 4 supplied 1/4" x 1" Type "A" screws.
9. Mount the UV Sterilizer (not shown) to a bulkhead directly after the Charcoal Filter. The UV should be mounted
vertically to displace air from the sterilizing chamber, with the electrical fitting on the top. The UV should be
plumbed with the inlet on the bottom and the outlet on top. Horizontal mounting is acceptable with outlet port
on top (pointed up) to displace air.
10. Attach the supplied Sea Cock Inlet Fitting Assembly, 1/2 " FNPT elbow with attached 1/2" hose barb to the
boats Sea Cock 1/4 turn ball valve.
11. Attach the supplied Brine Discharge Outlet Fitting Assembly, 1/2 " FNPT elbow with attached 3/8" Tube Fitting
to the boats Over board Discharge Fitting.
12. Attach the supplied Product Water Tank Connector 1/4" MNPT x 1/4" Tube Fitting to the 1/4" FNPT tap at the
Potable Water Tank.

Plumbing Connections

Caution: Always allow slack in water lines. Allow the line to enter or leave from the fitting in a straight manner
for several inches to ensure proper connection, to relieve stress to the fitting and tube or hose, and to allow
ease of detachment and reattachment during maintenance or repair. If water lines are pulled tight causing
them to bend at the fitting they will leak, allow air to enter, fail prematurely, and/or break the fitting that they
are attached to.
Fast-N-Tite Tube Fitting
CORRECT:
Straight and Parallel
with the Fitting for
at least 2 inches (5 cm)
System Installation Precautions and Information
Fast-N-Tite Tube Fitting
WRONG:
This will cause
air suction leaks
and water leaks
31