Recommended Power Wire Size To Booster Pump - Sea Recovery Aqua Mini 170 Owner's Manual

Table of Contents

Advertisement

Table 6: Aqua Mini 550/750
Operating Voltage
115 VAC
230 VAC
Properly sized Power Cables
Caution: DO NOT USE ROMEX TYPE SOLID CORE WIRE. SOLID CORE WIRE CAN EASILY BREAK
AND WILL NOT FIT OR SEAL INTO THE SUPPLIED STRAIN RELIEFS. USE ROUND JACKETED
STRANDED WIRE PREFERABLY WITH AN OUTER JACKET DESIGNATION OF SJO OR SIMILAR
COMPATIBLE WITH MARINE USE AND AN OILY ENVIRONMENT. FOR DC OPERATION FINE STRAND
WIRE, SIMILAR TO BATTERY CABLE, IS PREFERRED FOR MINIMAL RESISTANCE, MINIMAL VOLTAGE
DROP, AND EASE OF ROUTING (EASILY FORMED AND BENT).

Recommended Power Wire Size to Booster Pump

Table 7: Aqua Mini 170
Operating
Voltage
12 VDC
24 VDC
115 VAC
230 VAC
Table 8: Aqua Mini 350,500, & 750
Operating
Voltage
115 VAC
230 VAC
20
Maximum Load
Recommended Minimum Wire Size Length of run
Amperage
10 Ft / 3 meter
18.2 Ampere
12 AWG / 5 mm2
9.1 Ampere
14 AWG / 3 mm2
Maximum
Recommended Minimum Wire Size
Load
Length of run
Amperage
10 Ft / 3 meter
5 Ampere
14 AWG / 2 mm2
2.5 Ampere
14 AWG / 2 mm2
1 Ampere
14 AWG / 2 mm2
.5 Ampere
14 AWG / 2 mm2
Maximum
Recommended Minimum Wire Size
Load
Length of run
Amperage
10 Ft / 3 meter
6 Ampere
14 AWG / 2 mm2
3 Ampere
14 AWG / 2 mm2
20 Ft / 6 meter
30 Ft / 9 meter
10 AWG / 5 mm2
10 AWG / 5 mm2
12 AWG / 3 mm2
12 AWG / 3 mm2
20 Ft / 6 meter
30 Ft / 9 meter
14 AWG / 2 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
20 Ft / 6 meter
30 Ft / 9 meter
14 AWG / 2 mm2
12 AWG / 3 mm2
14 AWG / 2 mm2
14 AWG / 2 mm2
Sea Recovery Aqua Mini 170, 350, 550 and 750

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aqua mini 350Aqua mini 550Aqua mini 750

Table of Contents