Astria Valiant32ZP2 Installation And Operation Instructions Manual

Unvented (vent-free) tall-opening firebox

Advertisement

P/N 126691-01 Rev.A 02/2014
P126691-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for
the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for
the installation.
WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000
Btu/H.
Do not build a wood fire.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
Valiant32ZP2
US
Valiant32ZP3
Unvented (Vent-Free) Tall-Opening Firebox
Valiant36ZP2
Valiant36ZP3
Valiant42ZP2
Valiant42ZP3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Valiant32ZP2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Valiant32ZP2

  • Page 1 Installation and Operation Instructions Astria Unvented (Vent-Free) Tall-Opening Firebox P/N 126691-01 Rev.A 02/2014 Models ® Valiant32ZP2 Valiant36ZP2 Valiant42ZP2 Valiant32ZP3 Valiant36ZP3 Valiant42ZP3 P126691-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
  • Page 2: Table Of Contents

    Ceiling fans can create drafts that alter burner WARNING: Do not use a flame patterns. Altered burner blower insert, heat exchanger patterns can cause sooting. insert or other accessory not ap- proved for use with this firebox. www.Astria.US.com 126691-01A...
  • Page 3: Safety

    11. Provide adequate clearances around air openings. running installed gas log heater. Replace hood with INNOVATIVE HEARTH PRODUCTS model 109511-01 50", 109511-02 42", or 109511-03 36" only. This hood has been designed to keep the operation of your fireplace safe and efficient. www.Astria.US.com 126691-01A...
  • Page 4: Local Codes

    Before installation, consider the 4. Proper air for combustion and ventilation following: (page 7). 1. Where firebox will be located: Allow for wall and ceiling clearances (see Installa- tion Clearances, page 10). 2. Everything needed to complete fireplace installation. www.Astria.US.com 126691-01A...
  • Page 5: Product Specifications

    Top View 5/8" " " Indoor " Indoor/Outdoor " " Standoffs " " Built-In Side Nailing " Flanges " " " " " " " Front View Back View " " Figure 1 - Firebox Dimensions (32" Models) www.Astria.US.com 126691-01A...
  • Page 6 " (36" Models) Flanges " (42" Models) 35" (36" Models) 42" (42" Models) " " Front View " Back View (36" Models) (36" Models) (42" Models) " (42" Models) Figure 2 - Firebox Dimensions (36" and 42" Models) www.Astria.US.com 126691-01A...
  • Page 7: Air For Combustion And Ventilation

    2. Unconfined Space * Adjoining rooms are communicating only if 3. Confined Space there are doorless passageways or ventilation grills between them. Information on page 7 through 9 will help you classify your space and provide adequate ventilation. www.Astria.US.com 126691-01A...
  • Page 8 International Fuel Gas Code, ances. Direct-vent draws combustion or applicable local codes. air from the outdoors and vents to the outdoors. Example: 40,000 Gas water heater _________ Btu/Hr 39,000 Vent-free heater + ________ Btu/Hr 79,000 Total = ________ Btu/Hr www.Astria.US.com 126691-01A...
  • Page 9: Installation

    42" from top of firebox. For or cause odors. side clearances see Figure 5, page 10 • in high traffic areas • in windy or drafty areas * Unless the installed log set is rated at 10,000 Btu/Hr or less. www.Astria.US.com 126691-01A...
  • Page 10 D. Clearances from bottom of firebox to floor Follow all minimum clearances is 0". shown in this manual. www.Astria.US.com 126691-01A...
  • Page 11 " These minimum clearances replace any other recommended 86" clearances supplied with your ANSI Z21.11.2 approved gas logs. TOP VIEW Figure 6 - Minimum Mantel Clearances Figure 7 - Rough Opening for Installing for Built-In Installation in Wall www.Astria.US.com 126691-01A...
  • Page 12 Firebox and cabinet mantel can be installed Indoor Firebox directly on floor. A trim kit is included with mantel accessories. Follow instructions with mantel for installation. Nails or Wood Screws Nailing Flanges Indoor/Outdoor Firebox Figure 8 - Attaching Firebox to Wall Studs www.Astria.US.com 126691-01A...
  • Page 13 This hole will line up with hole in outer casing. Figure 10 - Location of Knockout for Gas Line CAUTION: Do not use exces- sive force to remove the knock- out. Too much force may damage the firebrick concrete insert. www.Astria.US.com 126691-01A...
  • Page 14 Front Hole Hood Ring Loosen Top Remove/Replace Screen Screws Screw Side Screws Figure 13 - Hood Placement Figure 14 - Installing Fireplace Screen (Model May Vary From Illustration) (Model May Vary From Illustration) www.Astria.US.com 126691-01A...
  • Page 15: Replacement Parts

    W32TU - 32" Wall Mantel, Unfinished, PT42P - 42" Platinum Traditional VENT FREE GAS LOGS W32TO - 32" Wall Mantel, Oak Stain, Please visit www.IHP.US.com for specific Traditional models, sizing, specifications and dealers C32TU - 32" Corner Mantel, Unfinished, in your area. Traditional www.Astria.US.com 126691-01A...
  • Page 16: Parts

    PARTS 32", 36", AND 42" MODELS 19 21 20/20a www.Astria.US.com 126691-01A...
  • Page 17 Gas Knock-Out Cover • • • 107128-01 Gas Conduit • • • 21379 Gas Conduit • • 21380 Gas Conduit • • 20042 Cover Plate • • • Side Damper Weldment • • • ** Not a field replaceable part. www.Astria.US.com 126691-01A...
  • Page 18 108434-04 Left Refractory Stacked White • 122810-01 Left Refractory Herringbone White • 108430-04 Rear Refractory Stacked White • 122808-01 Rear Refractory Herringbone White • 108432-04 Right Refractory Stacked White • 122809-01 Right Refractory Herringbone White • 126065-01 Bottom Refractory White • • www.Astria.US.com 126691-01A...
  • Page 19 107812-05 Left Refractory Stacked White • 122818-01 Left Refractory Herringbone White • 107816-05 Rear Refractory Stacked White • 122816-01 Rear Refractory Herringbone White • 107814-05 Right Refractory Stacked White • 122817-01 Right Refractory Herringbone White • 126067-01 Bottom Refractory White • • www.Astria.US.com 126691-01A...
  • Page 20 THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 21: Warranty

    WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126691-01A...
  • Page 22 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126691-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P126691-01...

Table of Contents