8.2.

Soft Dry Mode Operation

• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
• During Soft Dry operation, the Indoor Fan will operate at low speed.
• The operation will be switched on and off for up to 10 minutes "ON" and 6 minutes "OFF". Once Soft Dry operation is turned
off, it stops for 6 minutes.
Time Delay Safety Control
• Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Starting Current Control
• Same as Starting Current Control for Cooling Mode operation.
Anti-Freezing Control
• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Compressor Reverse Rotation Protection Control
• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
• Fan speed off and on at Lo speed.
• Deodorizing Control.