Audio; Slow Charging; Test Flash; Trouble Shooting - Hensel Pro MINI 1200 AS User Manual

Power pack
Table of Contents

Advertisement

Available languages

Available languages

User manual // Pro Mini 1200 AS Power Pack
8
5
7:
FC
6:

AUDIO

3:
SLOW
15:
TEST
12:
READY
5, 11
42
Dim Mode
The dim mode is intended to prolong the life span of the
modeling lamp. If the modeling lamp level is adjusted to
FULL or to PROP between 10.0 and 9.1, the output is
automatically dimmed by approximately 1 f-stop after
stopping working with the flash unit for longer than 35
minutes (default value). Pressing any button you like
switches the modeling light to the previously adjusted un-
dimmed level. If required, this default value can be
changed by entering a value from 5 minutes up to 95
minutes. To do that, press dial 8 to enter a new value
shown on display 5. Wait for 3 seconds and the display
changes to the flash power setting.
Flash Check
lf this mode is switched on using switch 7 (LED indicator
lights up), then the modeling lamp is turned off after a
flash and is turned on after recharging to the adjusted
power level. This shows correct charge as well as readi-
ness to flash. The flash check mode guarantees that the
flash heads have triggered when more than one flash unit
is used.
Audio
Readiness to flash after charging is signaled with a tone.
This tone can be turned on (control LED lights up) or off
using the AUDIO switch 6.

Slow charging

By pressing button 3 the charging time can be doubled.
This provides more flashes per accumulator charge.

Test flash

By pressing button 15 test flashes can be released. The
green light of the LED control lamp 12 signals readiness
to flash.

Trouble shooting

The following errors are shown on both LED displays 5
and 11:
E1: Overheat
E2: Overcharge
E3: No ignition
HENSEL-VISIT International GmbH