1. Spark electrode does not produce spark.
a. Spark electrode broken - replace.
b. Ignitor wire may not be attached to spark electrode -
attach.
c. Ignitor wire damaged - replace.
d. Piezo ignitor defective - replace.
2. Spark electrode produces spark but pilot does not light.
a. No gas to heater - turn on gas.
b. PILOT position not properly aligned - turn gas control knob
to PILOT position and depress.
c. Pilot is blocked from spider web or dirt - clean pilot, see Page
14.
3. Pilot flame does not stay "ON" when control knob is
released.
a. Control knob in PILOT position not completely depressed or
held in long enough.
b. INTERLOCK latching device is operative - see "Lighting
Instructions," Page 12, Step 9.
c. Thermocouple not tightened into gas control - tighten
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
INDEX
PART NO. DESCRIPTION
NO.
1
13347
CASING SIDE ASSEMBLY - LEFT
2
SR-180
CASING BACK
3
R-2313
PIEZO IGNITOR
4
SR-008
CASING SIDE ASSEMBLY - RIGHT
5
SR-113
VALVE BRACKET
6
R-6563
GAS VALVE -SIT
7
12438
TUBING - GAS VALVE TO BURNER
TUBING - INLET REGULATOR TO GAS
8
12437
VALVE
9
10753
INLET REGULATOR BRACKET
10
R-5097
INLET REGULATOR - NAT
10
R-5098
INLET REGULATOR - LPG
11
SR-158
TUBING - GAS VALVE TO PILOT
12
R-2314
ORIFICE HOLDER
13
R-2317
MAIN BURNER ORIFICE - NAT
13
R-2476
MAIN BURNER ORIFICE - LPG
14
R-2331
BURNER
PILOT ASSEMBLY (LPG ONLY) (IN-
15
R-6308
CLUDES ITEMS 16 & 17)
PILOT ASSEMBLY (NAT ONLY) (IN-
15
R-6307
CLUDES ITEMS 16 & 17)
16
R-6310
PILOT THERMOCOUPLE
17
R-6309
SPARK IGNITOR
Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529
Page 16

TROUBLESHOOTING

4. Main burner does not ignite.
5. Heater keeps shutting "OFF" during normal operation.
PARTS LIST
SR-10T
INDEX
NS - NOT SHOWN
thermocouple.
d. Pilot flame not surrounding thermocouple - clean pilot, see
Page 14.
e. Inlet gas pressure too low, contact gas supplier.
f. Thermocouple defective - replace.
g. Gas control defective - replace.
a. Main burner orifice is blocked - clean, see "Main Burner Flame
Characteristics," Page 13. Attention: The number stamped
on the main burner orifice is a millimeter diameter.
b. Inlet gas pressure too low, contact gas supplier.
a. Pilot is blocked - clean pilot, see Page 14.
b. Inlet gas pressure too low, contact gas supplier
PART NO. DESCRIPTION
NO.
18
SR-179
PILOT BRACKET (NAT)
18
SR-032
PILOT BRACKET (LPG)
19
SR-153
ORIFICE SHIELD
20
R-2305
CHROME GRILL
21
SR-134
CASING LOUVER (2 REQUIRED)
22
SR-129
REFLECTOR ASSEMBLY
23
SR-135
HEAT SHIELD
24
R-1992
BULB CLIP
25
SRS-10
OPTIONAL FLOOR STAND KIT
NS
R-2390
IGNITOR WIRE
NS
SR-216
HARDWARE PACKAGE
16941-8-0314

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Sr-18t-3Sr-30t-3

Table of Contents