By utilizing the OPTEX's unique pyro-element,
HX series achieves high reliable detection
performance against false and missed alarms.
HX series provides stable and accurate
detection in outdoor severe environmental
conditions.
HX-40RAM: Battery operated model with IR
anti-masking feature.
Installation and connection methods differ
depending on the type and size of the
transmitter battery.
1
INTRODUCTION
BEFORE YOUR OPERATION
1-1
Warning
Do not repair or modify
product
Parallel
2.5 - 3.0 m
(8.3 - 10 ft.)
The check ( ) mark indicates recommendation.
The cross ( ) mark indicates prohibition.
Keep the product away from
the water
Tilt
-1-

INSTALLATION INSTRUCTIONS

CONTENTS
1
INTRODUCTION
1-1 BEFORE YOUR OPERATION
2
3
4
5
5-1 SPECIFICATIONS
Warning
Mount the unit securely
No.59-1547-2
N219
1
2
2
3
4
5
5
7
8
9
10
11
13
14
15
16
Caution

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HX-40RAM and is the answer not in the manual?

Questions and answers

Summary of Contents for Optex HX-40RAM

  • Page 1: Table Of Contents

    2-2 BATTERY PREPARATION conditions. INSTALLATION 3-1 DETERMING THE DETECTION LENGTH HX-40RAM: Battery operated model with IR 3-2 MOUNTING THE BATTERY anti-masking feature. 3-3 MOUNTING THE TRANSMITTER Installation and connection methods differ AND THE BATTERY BOX...
  • Page 2: Parts Identification

    1-2 PARTS IDENTIFICATION Bracket base Base Screw (3×10 mm) Battery box Terminals Main unit Hood PIR sensor (Don not touch) Anti-masking infrared LED Bracket Shaft cover Screw (4×20 mm) Lock screw (M4×35 mm) Lens LED indicator Cover Area masking seal Lock screw Accessories Battery leads...
  • Page 3: Preparations

    2-2. 2-1 TRANSMITTER PREPARATION The transmitter that HX-40RAM can accommodate are either 1 or 2 below: Note that a transmitter with greater dimensions than these is not applicable. Installation position for the transmitter and the battery box differ depending on their dimensions.
  • Page 4: Battery Preparation

    2-2 BATTERY PREPARATION -Battery Sharing Possible Case (See P5) Power supply is available from the battery box to both HX-40RAM and the transmitter. Transmitter HX-40RAM Battery box Note that the battery type shall be the same as that used for the transmitter.
  • Page 5: Determing The Detection Length

    3-1 DETERMING THE DETECTION LENGTH Apply masking seal to set the detection length directly on lens. To set an length shorter than the standard 12 meters, select one of the three patterns and apply the appropriate masking seal to the lens. 4.0 m (13.3 ft.) 9.0 m (30 ft.) 5.5 m (18.3 ft.)
  • Page 6 Place the battery lead (included in the Connect the alarm cable to the set) and a dummy battery in the battery transmitter and close the cover. case of transmitter. Transmitter BATTERY LEAD(red) CR123A Put the alarm wire outside BATTERY LEAD(black) through the wiring hole Alarm cable 1/2AA...
  • Page 7: Mounting The Transmitter And The Battery Box

    3-3 MOUNTING THE TRANSMITTER AND THE BATTERY BOX Using a Velcro tape (included in the set), Fix the base to the wall surface. fix the transmitter to the main unit. Example of Case 1 Example of Case 2 (See 2-1) (See 2-1) Velcro tape Mount the main unit and the lens onto...
  • Page 8: Mounting The Bracket

    3-4 MOUNTING THE BRACKET Using the bracket makes it possible to adjust the unit horizontally by ± 90 degrees. In cases where the ground is uneven and therefore not parallel with the base of the unit, it is possible to adjust the unit vertically by ± 20 degree (refer to 3-5) Caution>>...
  • Page 9: Adjusting The Vertical Angle

    Install the base on the bracket. Decide the horizontal angle, and tighten the adjustment screw clockwise. Adjustment screw Install the Main unit and cover on the base. Complete the 3-5 “ADJUSTING THE Caution>> VERTICAL ANGLE”. Do not tighten the up-down lock Remove the cover and the Main unit to screw.
  • Page 10: Wiring

    (the size of such transmitters should be small enough to be accommodated in the HX-40RAM internal case 1) / 2)). used • To output LOW BATTERY SIGNAL to...
  • Page 11: Setting

    SETTING 4-1 FUNCTION Dip SW 1 WALK TEST MODE 2 BATTERY SAVING TIMER 3 IMMUNITY 4 TROUBLE OUTPUT TYPE 5 LOW BATTERY OUTPUT 6 LED ON/OFF ANTI-MASKING PIR SENSITIVITY (p13) SENSITIVITY (p13) Do not touch -WALK TEST MODE Dip switch POSITION FUNCTION •LED will lights at the time of detection regardless...
  • Page 12 -TROUBLE OUTPUT TYPE Dip switch Select the contact point output form with the TROUBLE OUTPUT TERMINAL. POSITION FUNCTION N.C. N.C. signal is output to the TROUBLE OUTPUT (factory default) TERMINAL. N.O. N.C. N.O. signal is output to the TROUBLE OUTPUT N.O.
  • Page 13: Anti-Masking

    -LED ON/OFF Dip switch FUNCTION POSITION The LED does not light even at the time of (factory default) detection. The LED lights when someone is detected. -PIR SENSITIVITY PIR SENSITIVITY POSITION FUNCTION High sensitivity HIGH MIDDLE Middle sensitivity (factory default) Low sensitivity HIGH MIDDLE...
  • Page 14: Area Adjustment

    -LED INDICATION Light Blink STATUS LED Indication Alarm Red lights Warm-up period Red blinks Anti-Masking booting Red blinks 2 times and goes off for 5 sec. (Anti-Masking start up) This movement is repeated. Trouble Red blinks 3 times and goes off for 3 sec. Anti-Masking output This movement is repeated.
  • Page 15: Specifications

    SPECIFICATIONS 5-1 SPECIFICATIONS HX-40RAM Model Passive infrared Detection method PIR Coverage 12 m (40 ft.) 85° wide / 94 zones Distance limit 4 m, 5.5 m, 9 m, 12 m (13 ft, 18 ft, 30 ft, 40 ft.) Detectable speed 0.3 –...