Installation Instructions
6. Install the alarm on the mounting
bracket and rotate the alarm in the
direction of the "ON" arrow on the
cover until the alarm ratchets into
place (this ratcheting function
allows for aesthetic alignment).
Note: The alarm will mount to the
bracket in 4 positions (every 90
degrees). NOTE: battery backup is
automatically activated when the
unit is rotated onto the bracket.
7. Turn on the AC power. The green AC Power On Indicator
should be lit when the alarm is operating from AC power.

Step 4: Testing the Alarm

!
CAUTION: Due to the loudness (85 decibels) of the
alarm, always stand an arms length away from the
unit when testing.
After installation, TEST THE UNIT'S ELECTRONICS by pressing
and releasing the test/reset button. You will hear one beep on
the button push, and will then hear the following sequence of
"beeps":
Three long beeps.
Pause.
Three long beeps.
Single beep to reset.
Weekly testing is required! If at anytime it does not perform as
described, verify power is connected correctly. Clean dust and
other buildup off the unit. If it still doesn't operate properly call
the Product Support Line at 1-800-880-6788.