Changing The Filters; Maintenance; Replacement Filters - Waterworld new millenium Installation & Service Manual

Reverse osmosis drinking water systems
Table of Contents

Advertisement

CAUTION: ANY REPLACEMENT FILTERS OR MEMBRANES NOT RECOMMENDED BY THE
FACTORY CAN CAUSE SEVERE DAMAGE TO THE SYSTEM AND VOID ALL WARRANTIES.
Before starting maintenance, check the reverse osmosis system for TDS reduction to determine
if membranes will or will not need to be changed.
If TDS reduction is less than 90% concentration, then the membrane should be replaced.
1)
Shut off the water supply to the system.
2)
Close storage tank ball valve.
3)
Open the dispensing faucet to depressurize the system. (Allow 2 to 3 minutes).
4)
Remove the filter housings by turning counter-clockwise.
5)
Remove old filters and clean housings with a mild soap and water solution.
6)
Check o-rings for deterioration and lubricate with an approved FDA silicone lubricant for
o-rings or replace if needed.
7) Insert the appropriate new filters inside housings and replace them by mounting them
in to position. Make hand tight plus 1/8 to ¼ turn with housing wrench. DO NOT OVER-
TIGHTEN. Over-tightening will cause cracks and leaks if not careful.
CAUTION: ALWAYS MAKE SURE THAT "O"-RINGS ARE SEATED PROPERLY INSIDE
SUMPS BEFORE TIGHTENING CANISTERS.
8)
If a membrane needs changing, remove the inlet tubing to the housing, unscrew the cap,
and pull the membrane out using a needle nosed pliers. Clean the inside of the membrane
housing with a mild soap and water solution.
9)
Lubricate the o-rings on the membrane permeate tube with an approved FDA silicone lu-
bricant. Insert into the housing with brine seal towards the opening. Make sure membrane
is fully inserted and seated into place.
10) Reseal the membrane housing with the cap and reconnect tubing.
11) To replace the carbon in-line post filter, remove the tubing and fittings at either end. Clean
the old Teflon tape off the threads and apply new tape. Screw the fittings into the new
cartridge paying close attention to the flow direction. Reinsert tubing.
1) First Stage:
2) Second Stage:
3) Third Stage:
4) Fourth Stage:
5) Fifth Stage:

CHANGING THE FILTERS

MAINTENANCE

REPLACEMENT FILTERS:

item# CP110
item# UDF-10
item# 32-250-125-975
item# TW30-1812-75
item# K2540-BB