Starting Diag In The Protection Cancel Mode; Canceling Diag - Yamaha DSP-AX2 Service Manual

Yamaha av amplifier service manual
Hide thumbs Also See for DSP-AX2:
Table of Contents

Advertisement

No.
DIAG menu
11
IF STATUS
12
DSP RAM CHECK
13
SUM/VER/PORT
Starting DIAG
Press the "POWER" (STANDBY/ON) key of the main unit while pressing the "EFFECT" key and the "6CH INPUT"
key located in the sealing panel of the main unit simultaneously, and DIAG will be activated.

Starting DIAG in the protection cancel mode

If the protection function works and causes hindrance to trouble diagnosis, cancel the protection function as de-
scribed below, and it will be possible to enter the DIAG mode. (The protection function other than the excess current
detect function will be cancelled.)
Press the "POWER" (STANDBY/ON) key while pressing the "EFFECT" key and the "6CH INPUT" key simulta-
neously. At this time, keep pressing the "EFFECT" key and the "6CH INPUT" for 3 seconds or longer.
In this mode, " ZONE 2 " in the FL display of the main unit flashes.
CAUTION!
Using this product with the protection function cancelled may cause damage to itself. Use special care for this point
when using this mode.

Canceling DIAG

Turn off the power by pressing the "POWER" (STANDBY/ON) key of the main unit or the "POWER" key of the
remote control unit.
CAUTION: When canceling this function, check that DIAG menu No.9 PRESET (memory initialization inhibited/
reserved) has been set. (To keep the user memory, be sure to select "INHIBIT" (initialization inhibited) from the No.9
PRESET menu before canceling the DIAG function.)
Sub-menu
16. YSS2
17. YSS3
DSP RAM check
1. Version
2. Checksum (ALL/PROG)
3. Checksum (232C/MAKER)
4. PORT (check of port settings for judging micrprocessor function)
DSP-AX2
Remote control code (key)
---------
---------
7A---0A (CD SKIP +)
7A---0D (CD REW)
---------
---------
---------
8