Thermal Status Report And Fan Control - Compal JHL90 Service Manual

Table of Contents

Advertisement

JHL90 Service Manual
Brightness level
changed
Contrast level changed SMI
CoverLid close
Display toggle
Battery in critical low
Battery in low state
Standby request
Battery pack plugin
Battery pack removed SMI
Suspend To RAM
request
Save To DISK request
Docking in
AC plugin
AC removed
Modem ringin
PME signal active

12.11 Thermal Status Report and Fan Control

EC will control fan on/off function according to the CPU temperature (EC will
get temperature from thermal sensor through SMBus). Fan will be off when
temperature below speed 1 speed down temperature, and if temperature over EC
Shutoff temperature five times, EC will auto turn off system to protect CPU. The
following table is detailed settings.
12.11.1.1 Fan control by Voltage
• EC will output voltage to control fan directly. (DTS/Tdiode Thermal Policy)
Speed stage
Speed 0
Speed 1
Speed 2
Speed 3
Speed 4
Speed 5
Speed 6
(Throttling start)
2-34
SMI
-
-
A1h
-
-
A2h
SMI
-
-
A6h
SMI
-
-
Ach
SMI
SMI
-
B2h
SMI
-
-
B3h
SMI
-
-
B4h
SMI
-
-
B5h
-
-
B6h
SMI
-
-
B8h
SMI
-
-
B9h
SMI
-
-
Bah
SMI
-
-
C7h
SMI
-
-
C8h
SMI
-
-
Cah
SMI
SMI
-
Ceh
Speed down
temperature (°C)
0
45
53
58
63
68
95
SCI
-
-
SMI
-
-
SCI
-
-
SCI
-
-
SCI
SWI
-
SCI
-
-
-
-
-
SBS
-
-
SBS
-
-
SCI
-
-
-
-
-
SCI
SWI
-
SBS
-
-
SBS
-
-
-
SWI
-
SCI
SWI
-
Speed up
temperature (°C)
50
55
60
65
70
100
105 (DTS)
(Shutdown temp)
-
11h
-
-
12h
-
-
16h
-
-
1ch
-
-
22h
-
-
23h
-
-
24h
-
-
25h
-
-
25h
-
-
28h
-
-
29h
-
-
2ah
-
-
37h
-
-
38h
-
-
3ah
04
-
3eh
02
Fan 1
RPM
0
2500
3000
3400
3800
4200
4200

Advertisement