Connection

(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX) SERIAL PORT OF THE PC(COM1)  SERIAL CABLE  RS-485 CONVERTER 
RS-485 CONTROL CABLE
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
485 Control Board Connection Port
RS-485 Communication establishment initial value.
Item
Initial value
When making a control system to control the camera, please use to the protocol SAMSUNG-T,
SAMSUNG-E, PELCO-D , PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, GE, AD.
When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer skin inside the
RS-485 CONTROL TERMINAL.
BLUE (ALARM OUT)
GRAY (EXT_D/N IN) You can switch to Day&Night Mode by connecting an external
BLACK (GND)
:
Used for earth-grounding.

USING COAXIAL COMMUNICATIONS

• Coaxial Communications System
• OSD Control method
CAMERA
SET
UP
DOWN
LEFT
RIGHT
16_ Connection
(+) CONNECTION TERMINAL
(-) CONNECTION TERMINAL
Camera ID
1
:
:
signal to this terminal.
BAUD RATE
UART MODE
9600
DVR
MENU/ENTER
UP KEY
DOWN KEY
LEFT KEY
RIGHT KEY
RS-485 Control Port
(485+)
(485-)
RET PKT
8-N-1
ENABLE
CONTROLLER
OSD KEY
JOYSTICK UP
JOYSTICK DOWN
JOYSTICK LEFT
JOYSTICK RIGHT