InstAllAtIon - DUAl FUel
connect to tHe GAs sUPPlY
Means of isolation shall be provided at
the shut off point by either an approved
quick connect device or a Type 1 manual
shut off valve. The outlet of the quick
connect device shall be at, or below, the
horizontal position.
Connection to the gas supply should be
made using the Aquaknect AS/NZS 1869
class B hose assembly with an internal
diameter of not less than 10mm and
regulator (regulator for use with natural
gas)
For operation on nG
The appliance regulator provided must be
oriented so that the pressure nipple (on
the outlet) is accessible. The governor
must be fitted to the supply line.
For operation on lPG (propane)
The pressure test point fitting provided
must be fitted to the supply line.
NOTE: The temperature rise of the areas
at the rear of the cooker that are likely to
come into contact with the flexible hose
do not exceed 70˙C.
The inlet to the cooker is ½" BSP internal
situated at the rear right corner. Fit the
bayonet connection. This should be
located so as to ensure that the flexible
connector hose does not kink.
Under no circumstances should the
flexible connector be allowed to
come into contact with the vertical
oven flue tubes on the rear of the
appliance.
Use a 900mm - 1200mm length of flexible
connector.
Ensure that all pipework is of the correct
rating for both size and temperature.
Natural Gas- Installations must conform
to local codes or, in the absence of lo-
cal codes, with AS:5601 as well as the
requirements of any local council, gas,
electricity authority or other statutory
regulation.
After installation, make sure all con-
nections are gas sound.
checking the gas supply
Check the manometer zero point is
correct. Connect the manometer to the
cooker pressure test point. Turn on the
gas supply and the electricity then try to
ignite the gas.
Note: It will take additional time to light
the gas for the first time as air needs to
be purged from the pipes.
Check the operating pressure for the par-
ticular gas types.
NG 1.00 kPa, LPG 2.75 kPa
For lPG cookers
Adjust the regulator if necessary (this may
be remote from the cooker).
For nG cookers
Regulators are supplied pre-adjusted
and configured by the component maker
for use with Natural Gas. The appliance
installer should not be required to make
an adjustment to obtain the correct outlet
pressure setting. Regulator outlet pressure
should be checked when