connect to tHe electRIcItY sUP-
PlY - DUAl FUel
Warning :This appliance must be earthed.
The appliance must be installed by a com-
petent electrician using a double pole con-
trol unit of 32 ampere minimum capacity
with 3mm minimum contact separation at
all poles.
We recommend that the appliance is con-
nected by a qualified electrician who is a
member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regula-
tion.
1. Access to the mains terminal is gained
by opening the terminal block cover at
the rear of the appliance (use a small flat-
bladed screwdriver).
2. Connection should be made with
6.0mm
flexible twin and earth cable.
2
3. First strip the wires, then push the
cable through the cable clamp in the
terminal block cover.
4. Connect the cable to the terminal block
and tighten the cable clamp screw (see
diagram).
5. Close the terminal box, ensuring that
the cover is engaged on the locking tabs.
InstAllAtIon - DUAl FUel
Your appliance will be fitted with one of
the two terminal blocks below, Block A
Block B