Minimum clearance to combustible construction from appliance and vent surfaces:
Combustible Framing:
-
-
-
Combustible Finishing:
-
-
-
Rear Vent:
-
-
Top Vent:
-
-
* HORIZONTAL VENT SECTIONS - A minimum clearance of 1" at the bottom and sides and 2" at the top of
the vent pipe in all horizontal runs to combustibles is required except for clearances in appliance enclosures,
see "MINIMUM ENCLOSURE CLEARANCES" section. Use fi restop spacer W010-1777 (supplied).
* VERTICAL VENT SECTIONS - A minimum of 1" all around the vent pipe on all vertical runs to combustibles
is required. Use fi restop spacer W500-0096 (not supplied).
DO NOT BUILD INTO THIS AREA - IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE
FOR THE VENT. IN THIS 14" WIDE AREA CENTRED ALONG THE FRONT OF THE APPLIANCE, NO
*FINISHING MATERIAL
W415-0825 / 07.06.09
* Dimensions must be maintained for the facing kit to cover the opening.
0" to stand-offs
1" to bottom and sides of the vent pipe*
2" to top of the vent pipe*
0" to rear
0" to front face top and sides
13" recessed depth
39 1/8" to enclosure top from base of the unit
45 1/8" to ceiling from base of the unit
53 1/8" to enclosure top from base of the unit
53 1/8" to ceiling from base of the unit
COMBUSTIBLES ARE ALLOWED.
1 1 /2" MAXIMUM
14"
MINIMUM
1 1 /2"
*FINISHING
MAXIMUM
MATERIAL
OPENING
HEIGHT
MUST BE
34 1 /8"
OPENING WIDTH
MUST BE 20 1 /4"
WARNING
!
1 /4" *
MATERIAL
1 /4" FROM
13 1 /4"
*KEEP
FACING
SIDE OF
UNIT.