Component 15 Khz Signal Adjustment; Component Hdtv Signal Adjustment; Factory Settings - Pioneer PDP-R03E Service Manual

Media receiver
Table of Contents

Advertisement

(5) Component 15 kHz signal adjustment

Adjustment item
1
Setup
2
MAIN component
15 K Y level
adjustment
3
MAIN component
15 K color density
adjustment
4
MAIN component
15 K Cr level
adjustment

(6) Component HDTV signal adjustment

Adjustment item
1
Setup
2
MAIN component
HDTV contrast
adjustment

2. Factory settings

(1) Data Copy
Adjustment item
1
Data Copy
(2) Delivery setup
Adjustment item
1
Delivery setup
* Finally turn off the power to exit from the process adjustment mode.
Description
1. Select component 15 kHz.
2. Select component source.
Adjust TB1274_MAIN output (TP803) to 0.7 Vp-p.
Adjusted value: 0.7 ±0.05 V
Adjust TB1274_MAIN output
(TP802) to 0.35 Vp-p.
Adjusted value:
0.35 ±0.025 V
Adjust TB1274_MAIN output
(TP801) to 0.35 Vp-p.
Adjusted value:
0.35 ±0.025 V
Description
1. Input HDTV (1080i) component signal.
2. Select component source.
Turn off the PEAK ACL control.
Adjust the output (TP815) of IC810 (11) to have
1.1 Vp-p from the pedestal level.
Adjusted value: 1.1 ±0.05 V
Description
1. Using the adjustment key, set "ON" in the DATA
Description
Press the Delivery Setup button located on the remote
controller, or position the cursor on the INDUSTRY
INIT line, set the line to ON with the ADJ key, and then
press the ENTER key. The adjustment is finished
when the line turns OFF,
Adjustment procedure
Color bar signal including 100% white, like split
field color bar
0.35V
0.35V
Adjustment procedure
Color bar signal including 100% white, like split
field color bar
Adjustment procedure
COPY line. Wait until "OFF" is displayed instead.
Finally turn off the power to quit the process
adjustment mode.
Adjustment procedure
PDP-R03E
101

Advertisement

Table of Contents
loading

Table of Contents