Troubleshooting; Error Codes And Messages; Internal Device Error Codes; Table 12 - Internal Error Codes - DCS 900E User Manual

Hide thumbs Also See for 900E:
Table of Contents

Advertisement

dCS 900E / 902E User Manual
dCS Ltd
T
S
ROUBLE
HOOTING

Error Codes and Messages

Internal Device Error Codes

Manual part no: DOC0029021E1
Contact
on + 44 1799 531 999
dCS
(inside the UK replace + 44 with 0)
The error codes reported by dCS 900 & 902 provide an effective means to
diagnose the majority of problems that may be encountered in use - including
problems with the overall system the unit operates in, internal device warnings
and internal device failures. Please note that through damage or component
failure, the unit self check may fail to operate. If this happens, please contact
your distributor or dCS for assistance.
Sometimes the unit may misbehave. If there is an internal reason, an internal
device error code may be displayed as follows:
Err.xy
an error xy (see table below) has been detected
xy
where
values have the following meanings:
Code
Description
2
01
E
memory (EEPROM) not present
02
Error initialising DSP
03
Error loading DSP
04
Error initialising DSP for coefficients
05
Error initialising DSP for coefficients
06
Error loading DSP coefficients
07
Error loading DSP coefficients
08
Error sending command
09
Error sending command
10
Error sending command
11
Error sending command
12
Error with LSB/MSB configuration
13
Error with LSB/MSB configuration
14
Error with LSB/MSB configuration
15
Error configuring FPGA
99
DSP error

Table 12 - Internal Error Codes

If you get any of these, please contact dCS, with as much information as
possible to help us re-create the problem. Some of these may have hardware
problems as their cause, some may have software.
Manual for Software Versions 1.3x to 1.5x
Page 58
th
12
June 2000
Document No: OS-MA-D0002-902.1E1
email to: more@dcsltd.co.uk
web site: www.dcsltd.co.uk

Advertisement

Table of Contents
loading

This manual is also suitable for:

902e

Table of Contents