dCS 900E / 902E User Manual
dCS Ltd
IMPORTANT!
Sample Rate Display
Manual part no: DOC0029021E1
Contact
on + 44 1799 531 999
dCS
(inside the UK replace + 44 with 0)
dCS equipment encodes messaging into the various data streams to enable
receiving equipment to tell what is going on, and to decide which wire is which,
in the unlikely event of user wiring errors. Not all equipment from other
manufacturers does this, so:
Take care when connecting Dual AES as it is easy to connect the wires in the
wrong order. If this is not detected, the Left and Right channels will be
swapped on the recording. Numbering each connector is a sensible
precaution.
The main LED display generally shows the sample rate, in kS/s. When other
parameters are set, it briefly shows the new setting (Word Length, Noise
Shaping, etc) then reverts to its normal display. In the case of an error condition,
it will display an error message.
If the unit is being slaved, the display also indicates which input connector it is
slaved to.
xxx
b xxx
r xxx
d xxx
. xxx
Important error messages are given below – a full list is given in the section
Error Codes and Messages
BadFs
Err.xy
Hot
Ouch
(blank)
The display is also used for Menu options.
Manual for Software Versions 1.3x to 1.5x
-
The sample rate, in kS/s (32, 44.1, 48, 88.2 or 96).
Slaved to
Clk
In.
Slaved to
AES Reference
Temporary display during locking – the unit has
detected the base reference sample rate and is
attempting to lock to it.
Temporary display during locking – the unit is lining
up
Clk Out
to
Clk
in.
on page 58.
The clock source is not in pull-in range, or is poorly
formatted. The unit cannot lock to it.
An error has been detected. Please refer to
"Internal Device Error Codes"
more specific details on error codes.
The unit is overheating, probably due to inadequate
ventilation. Please check positioning and cooling.
The "Hot" warning has been ignored and the unit is
getting so hot damage may follow.
If the display is completely blank for any significant
period, try switching off for 10 seconds then
switching on again. If this does not solve the
problem, contact your distributor or dCS.