LC32D44E/S/RU-BK/GY (1st Eddition)
Page
Line
Item
8/11
[M GAMMA 1-3]
1
M GAMMA R 1
2
M GAMMA G 1
3
M GAMMA B 1
4
M GAMMA R 2
5
M GAMMA G 2
6
M GAMMA B 2
7
M GAMMA R 3
8
M GAMMA G 3
9
M GAMMA B 3
10
M GAMMA WRITE
9/11
[M GAMMA 4-6]
1
M GAMMA R 4
2
M GAMMA G 4
3
M GAMMA B 4
4
M GAMMA R 5
5
M GAMMA G 5
6
M GAMMA B 5
7
M GAMMA R 6
8
M GAMMA G 6
9
M GAMMA B 6
10
M GAMMA WRITE
10/11
[ETC]
1
EEP CLEAR
2
EEP CLEAR B
3
STANDBYCAUSE RESET
4
AUTO INSTALLATION SW
5
OPTION
6
COUNTRY
7
L ERR RESET
8
L ERR STOP
9
DTV CLR
10
I2C-OFF
11/11
[COM-BIAS]
1
VCOM ADJ
2
TEST PATTERN

[6] Special features

* ERROR STANDBY CAUSE (Page 1/11)
The total time when the unit enters the standby due to operational error and cause of error are recorded on EEPROM as much as possible.
The values can be used to locate the fault for repair.
* EEP CLEAR (Page10/11)
Clear of process adjustment EEP value.
Description
0
0
0
0
0
0
0
0
0
OFF/ON
0
0
0
0
0
0
0
0
0
OFF/ON
OFF/ON
OFF/ON
OFF/ON
0/1
0
AUTO/EURO/UK
0
0/1
ENTER
ENTER
63
0
3 – 20
Remarks (adjustment detail, etc.)
W/B adjustment, gradation 1R adjustment value
W/B adjustment, gradation 1G adjustment value
W/B adjustment, gradation 1B adjustment value
W/B adjustment, gradation 2R adjustment value
W/B adjustment, gradation 2G adjustment value
W/B adjustment, gradation 2B adjustment value
W/B adjustment, gradation 3R adjustment value
W/B adjustment, gradation 3G adjustment value
W/B adjustment, gradation 3B adjustment value
EEP writing of adjustment values
W/B adjustment, gradation 4R adjustment value
W/B adjustment, gradation 4G adjustment value
W/B adjustment, gradation 4B adjustment value
W/B adjustment, gradation 5R adjustment value
W/B adjustment, gradation 5G adjustment value
W/B adjustment, gradation 5B adjustment value
W/B adjustment, gradation 6R adjustment value
W/B adjustment, gradation 6G adjustment value
W/B adjustment, gradation 6B adjustment value
EEP writing of adjustment values
Clear of all adjustment value
Clear of adjustment value of B mode
Reset of STANDBY CAUSE
1: * * * 0: * * *
Destination setting
LAMP ERR RESET Initializatio of L_ERR
LAMP ERR Inhibit L_LRR detection
Clear of DTV setting
I2C DATA execution
INVERTER drive frequency setting
INVERTER drive frequency setting