Daikin RQYQ140PY1 Operation Manual

Daikin RQYQ140PY1 Operation Manual

Vrv iii system air conditioner
Hide thumbs Also See for RQYQ140PY1:

Advertisement

MODELS
RQYQ140PY1
RQYQ180PY1
RQCYQ280PY1
RQCYQ360PY1
RQCYQ460PY1
RQCYQ500PY1
RQCYQ540PY1
Series
RQEQ140PY1
RQEQ180PY1
RQEQ212PY1
RQCEQ280PY1
RQCEQ360PY1
RQCEQ460PY1
RQCEQ500PY1
RQCEQ540PY1
RQCEQ636PY1
RQCEQ712PY1
RQCEQ744PY1
RQCEQ816PY1
RQCEQ848PY1

OPERATION MANUAL

System air conditioner
VRVIII System air conditioner
Conditionneur d'air VRVIII System
Sistema de acondicionador de aire VRVIII
Condizionatore d'aria a sistema VRVIII
Κλιµατιστικό µε σύστηµα VRVIII
Airconditioner met VRVIII Systeem
Ar condicionado VRVIII System
Руководство по эксплуатации
Кондиционер системы VRVIII
Operation manual
Betriebsanweisung
VRVIII System Klimaanlage
Manuel d'utilisation
Manual de operación
Manuale d'uso
Εγχειρίδιο λειτουργίας
Gebruiksaanwijzing
Manual de funcionamento
Kullanım kılavuzu
VRVIII System Klima
English
Deutsch
Français
Español
Italiano
Ελληνικά
Nederlands
Portugues
Русский
Türkçe

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RQYQ140PY1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin RQYQ140PY1

  • Page 1: Operation Manual

    Sistema de acondicionador de aire VRVIII Manuale d’uso Italiano Condizionatore d’aria a sistema VRVIII Εγχειρίδιο λειτουργίας Ελληνικά Κλιµατιστικό µε σύστηµα VRVIII Gebruiksaanwijzing Nederlands MODELS Airconditioner met VRVIII Systeem RQYQ140PY1 RQEQ140PY1 RQYQ180PY1 RQEQ180PY1 Manual de funcionamento Portugues RQCYQ280PY1 RQEQ212PY1 Ar condicionado VRVIII System RQCYQ360PY1 RQCEQ280PY1...
  • Page 2 Dopo averlo letto, conservare Daikin klimalarını satın aldığınız için teşekkür ederiz. Klimayı kullanmadan önce kul il presente manuale per potervi fare riferimento in seguito. lanma kılavuzunu dikkatlice okuyunuz. Bu size üniteyi nasıl kullanmanız gerektiği ve Si veda inoltre il manuale delle istruzioni in dotazione eğer herhangi bir sorun oluşursa yardım konusunda bilgi verecektir.
  • Page 4 Double-flow Multi-flow Corner Ceiling Suspended Wall Mounted 14.1 14.2...
  • Page 5: Table Of Contents

    RQYQ140PY1 RQEQ140PY1 RQCEQ540PY1 RQYQ180PY1 RQEQ180PY1 RQCEQ636PY1 VRVIII System air conditioner RQCYQ280PY1 RQEQ212PY1 RQCEQ712PY1 Operation manual RQCYQ360PY1 RQCEQ280PY1 RQCEQ744PY1 VRVIII-Q Series RQCYQ460PY1 RQCEQ360PY1 RQCEQ816PY1 RQCYQ500PY1 RQCEQ460PY1 RQCEQ848PY1 RQCYQ540PY1 RQCEQ500PY1 CONTENTS WARNING..Failure to follow these instruc- tions properly may result in per- 1.
  • Page 6 Do not use flammable materials (e.g., hairspray Do not longer use the air conditioner until a qual- ified service person confirms that the leakage or insecticide) near the product. has been repaired. Do not clean the product with organic solvents such as paint thinner.
  • Page 7 Do not wipe the controller operation panel Do not place water containers (flower vases, with benzine, thinner, chemical dustcloth, etc.) on the unit, as this may result in electric etc. shocks or fire. The panel may get discolored or the coating Consult your dealer regarding cleaning the peeled off.
  • Page 8: Specifications

    2. SPECIFICATIONS [Combination unit (Heat Recovery series)] Model RQCEQ280PY1 RQCEQ360PY1 RQCEQ460PY1 [Single unit (Heat Pump series)] Power supply Model RQYQ140PY1 RQYQ180PY1 Phase Power supply Frequency (Hz) Voltage 380-415 380-415 380-415 Phase Nominal cooling capacity (kW) 28.0 36.0 46.0 (Hz) Frequency...
  • Page 9: What To Do Before Operation

    This operation manual is for the following system mode) with standard control. Before initiating operation, This display shows the current operation mode. contact your Daikin dealer for the operation that cor- 8. Display “ ” (programmed time) responds to your system type and mark.
  • Page 10: Operation Range

    20.Fan speed control button NOTE Press this button to select the fan speed of your • Cooling operation: preference. If the air conditioner is operated continuously while 21.Operation mode selector button the indoor temperature is 21°C or below and the humidity is 80% or over, the interiors of the indoor •...
  • Page 11 FOR SYSTEMS WITHOUT COOL/HEAT SELEC- • The system need at least 5 minutes for TOR (Refer to figure 4) residual operation of drain pump device. Turning off the power immediately will cause Press the operation mode selector button sev- water leak or trouble. eral times and select the operation mode of EXPLANATION OF HEATING OPERATION your choice;...
  • Page 12 • The system does not go into operation if the Press the on/off button. room temperature is low. The operation lamp lights up and the system • The microcomputer automatically controls starts operation. the temperature and fan speed, so these Press the air flow direction adjust button (only cannot be set using the remote controller.
  • Page 13 NOTE TROLLER (Refer to figure 10) • The movable limit of the flap is changeable. Contact your Daikin dealer for details. (Only • When one outdoor unit is connected with several for Double-flow, Multi-flow, Corner, Ceiling- indoor units as shown in figure 14.1 (Heat Pump suspended and Wall-mounted.)
  • Page 14: Optimum Operation

    • It takes time for the room temperature to reach the set temperature. NOTE We recommend starting the operation in advance • Contact your Daikin dealer in case of chang- using timer operation. ing the combination or setting of group con- trol and two remote controller control systems.
  • Page 15: Seasonal Maintenance

    Watts of power. This is because cool/heat changeover is con- Turn off the power to conserve energy. trolled by the cool/heat selector. Ask your Daikin Clean the air filter and exterior. dealer where the remote control switch is •...
  • Page 16 It is necessary to clean defrost operation. the interior of the indoor unit. Ask your Daikin This is the noise of refrigerant caused by flow stop dealer for details on cleaning the unit. This opera- or flow change.
  • Page 17: Trouble Shooting

    3. Operation lamp • This is because the crankcase heater is warm- 4. Malfunction code ing the compressor so that the compressor Measure: Notify your Daikin dealer and report the can start smoothly. malfunction code. 9-15 IT STOPS SOMETIMES If the system does not properly operate except for the above mentioned cases and none of the •...
  • Page 18 • When asking your dealer to repair, inform 3. The system operates but cooling or heating is insufficient; related staff of the details as follows: • Check if air inlet or outlet of outdoor or indoor unit • Product No. of air conditioner: is not blocked by obstacles.
  • Page 19 I Recommended replacement cycle of wear-out • Table 1 “Inspection Cycle” and “Maintenance Cycle” Lists parts [The cycle is not the same as the warranty period.] Maintenance Cycle Inspection Name of Main Part [replacements and/ Cycle • Table 2 “Replacement Cycle” Lists or repairs] Electric motor (fan, Inspection...