ECONCEPT SOLAR ST
Sensor characteristics
The temperature sensors can be checked with a digital multimeter : disconnect the sensor from regulator and check
correspondence with the following tables .
NTC
T(°C)
R (
-10
54932
-5
42080
0
32505
5
25308
10
19854
15
15689
20
12483
25
9999
30
8060
35
6537
40
5332
45
4374
50
3608
55
2991
60
2492
65
2086
70
1754
75
1481
80
1257
85
1070
90
915
95
785
100
677
105
585
110
507
115
442
EN
T(°C)
)
cod. -- - 11/2010 (Rev. 00)
PT 1000
R (
)
-10
961.5
-5
980.75
0
1000
5
1019.25
10
1038.5
15
1057.75
20
1077
25
1096.25
30
1115.5
35
1134.75
40
1154
45
1173.25
50
1192.5
55
1211.75
60
1231
65
1250.25
70
1269.5
75
1288.75
80
1308
85
1327.25
90
1346.5
95
1365.75
100
1385
105
1404.25
110
1423.5
115
1442.75
T(°C)
R (
)
120
1462
125
1481.25
130
1500.5
135
1519.75
140
1539
145
1558.25
150
1577.5
155
1596.75
160
1616
165
1635.25
170
1654.5
175
1673.75
180
1693
185
1712.25
190
1731.5
195
1750.75
200
1770