ECONCEPT SOLAR ST
Table. 4 - Accessories
Ø 80
PIPE
BEND
PIPE SECTION
TERMINAL
FLUE
Connection to collective flues
C
83
If you are then going to connect the ECONCEPT SOLAR ST boiler to a collective flue or a single flue with natural
draught, the flue must be expressly designed by professionally qualified technical personnel in conformity with the cur-
rent standards and be suitable for airtight chamber units equipped with a fan.
In particular, flues must have the following characteristics:
•
Be sized according to the method of calculation stated in the current standards.
•
Be airtight to the products of combustion, resistant to the fumes and heat and waterproof for the condensate.
•
Have a circular or quadrangular cross-section, with a vertical progression and with no constrictions.
•
Have the ducts conveying the hot fumes adequately distanced or isolated from combustible materials.
•
Be connected to just one unit per floor.
•
Be connected to just one type of unit (or all and only forced draught units or all and only natural draught units).
•
Have no mechanical suction devices in the main ducts.
•
Be at a lower pressure, all along their length, under conditions of stationary operation.
•
Have at their base a collection chamber for solid materials or condensation equipped with a metal door with an airtight closure.
EN
1 m M/F
45° M/F
90° M/F
with test point
air, wall
fumes, wall with antiwind
Split air/fumes 80/80
C
43
fig. 24 - Examples of connection to flues (
cod. -- - 11/2010 (Rev. 00)
Air
inlet
1KWMA83W
1.0
1KWMA65W
1.2
1KWMA01W
1.5
1KWMA70W
0.3
1KWMA85A
2.0
1KWMA86A
-
1KWMA84U
-
= Air /
= Fumes)
Losses in m
eq
Fume exhaust
Vertical
Horizontal
1.6
2.0
1.8
2.0
0.3
-
5.0
12.0
C
43
19