Pre-Installation; Receiving & Installing The Fryer; Leveling - ULTRAFRYER ZRT3-H Operation Instruction Manual

14 & 18” model with ez dock filtration
Table of Contents

Advertisement

PRE-INSTALLATION: Safe and satisfactory operation of a Model ZRT3-H gas fryer depends on its proper installation. Installation must conform
to local codes or, in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1 (latest edition). In Canada, gas installa-
tion shall be in accordance with the current CAN/CGA B 149.1 and .2 installation codes and/or local codes.
GENERAL: Each Model ZRT3-H fryer should be installed as follows:
A.
Placed beneath a properly designed exhaust hood
B.
Installed by a licensed plumber.
C.
Connected to the type gas for which the unit was fabricated as shown on the rating plate.
D. Connected to the proper size pressure regulator installed in the gas supply line and adjusted to the proper manifold pressure.
E.
Connected to the main gas supply line with the proper size supply line.
F.
Restrained by use of a restraining device to avoid splashing of hot liquid and to assure tension cannot be placed on the flexible gas line or
fittings.CLEARANCES: The appliance must be kept free and clear of all combustibles. The minimum clearance from combustible and
non-combustible construction is 6" (152 mm) from the sides, and 6" (152 mm) from rear. The fryer may be installed on combustible floors.
NOTE: Adequate clearances must be provided for servicing and proper operation.
STANDARDS: Installation must be planned in accordance with all applicable state and local codes, taking into account the following standards:
A.
The fryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that
system at pressures in excess of 1⁄2 psig (3.45kPa). In Canada, gas installation shall be in accordance with the current CAN/CGA B 149.1
and .2 installation codes and/or local codes.
B.
The fryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply
piping system at pressures equal to or less than 1⁄2 psig (3.45kPA).
C.
When installed the fryer must be electrically grounded in accordance with local codes, or in the absence of local codes, in accordance with the current
National Electrical code ANSI/NFPA 70 (latest edition). In Canada electrical installation must be in accordance with the current CSA C22.1 Canadian Elec-
trical Code and/or local codes.
D. Other applicable nationally recognized installation standards such as:
1.
National Fuel Gas Code ANSI Z223.1 (latest edition)
American Gas Association
1515 Wilson Blvd.
Arlington, VA22209
2.
NFPA Standards #54, #94 and #221 (latest edition)
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110
3.
ANSI Z21.69/CAN/CGA-6.16 AND Z21.41/CAN1 6.9
E.
Exhaust hood, when installed must conform to the current NFPA 54-1 and Canadian CAN/CGA-1.11 (latest edition)
NOTE: Local building codes will usually not permit a fryer with its open tank of hot oil to be installed immediately next to an open flame
of any type, whether a broiler or an open burner or range. Check local codes before beginning installation.
AIR SUPPLY AND VENTILATION: The area around the appliance must be kept clear of any combustible or flamable products and avoid any
obstruction to the flow of ventilation air as well as for ease of maintenance and service. NOTHING is to be stored in the interior of the
fryer's cabinet except the filter tub assembly.
A.
A means must be provided for any commercial, heavy duty-cooking appliance to exhaust combustion wastes outside of the building. It is
essential that a fryer be set under a powered exhaust hood or that an exhaust fan be provided in the wall above the unit, as exhaust tempera-
tures are in the vicinity of 400°F (204ºC).
NOTE: Strong exhaust fans in a hood or in the overall air conditioning system can produce slight air drafts in the room, which can interfere
with burner performance and be hard to diagnose. Air movement should be checked during installation and if burner problems persist,
make-up air openings or baffles may have to be provided in the room
B.
Exhaust temperature, in addition to the open tank of hot oil, make the storage of anything on shelving over or behind the fryer unsafe.
C.
Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and installing any hood.
D. Provisions must be made for an adequate supply of fresh air and adequate clearance must be maintained for air openings into the combus-
tion chamber.
RECEIVING & INSTALLING THE FRYER
A. UNPACKING: Check that the container is upright. Use an outward prying motion – DO NOT USE A HAMMER - to remove the
carton. Check the fryer(s) for visible damage; if such damage has occurred do not refuse shipment, but contact the carrier and file the
appropriate freight claims.
B.
INSTALLING: Roll the assembled fryer bank into the building, proceed to next paragraph.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.

LEVELING:

A.
When the fryer is placed in its operating location check to be sure it is level. If not, loosen the casters and insert the appropriate number
of shim plates between leg and caster plates then retighten the caster bolts.
B.
If the floor is smooth and level, adjust to the high corner and measure with a spirit level. If the floor is uneven or has a decided slope,
level the unit with metal shims.
NOTE: A caster may not return exactly to the same position after being moved, which may require re-leveling after each move.
.