LAMP INSTALLATION
CAUTION: DO NOT touch the glass surface when handling the quartz lamps. The oil from your hands creates hot
spots that will diminish the life of the lamps. When handling, grip the metal end caps.
1. Remove the top of the unit to access the lamps. Two lamps are required for operation,
2. Remove the inner lid. Avoid handling or bending the specular reflector shield attached to the lid.
3. Install lamps by inserting the metal end caps into the white porcelain insulators, fitting the lamps snugly in place
and attaching lead to any terminal on insulator.
4. Replace inner lid. Proper positioning places the air deflector on the side of the fan/control box. Secure at all six
points, required screws are in hardware packet.
5. Replace top, required screws are in hardware packet.
POWER CORD INSTALLATION
When installing a unit without a power cord (supplied upon request), we recommend a Type SO or SOW-A, #12 AWG 3-
conductor cord, rated 20 amps, 250 volts.