Troubleshooting; Maintenance - Marco Ecoboiler UC4L Instructions Manual

Hide thumbs Also See for Ecoboiler UC4L:
Table of Contents

Advertisement

T ROUBLESHOOT ING:
The Ready/Status light signals various errors or problems. A cycle of red flashes indicates an error.
The number of flashes in a cycle corresponds to the symptom in the table below:
Status/Diagnost ic light guide:
No of
flashes
Water level below elements. Normal
2
3
Temperature sensor failure (o/c)
4
5
Temperature sensor failure (s/c)
6
M AINT ENANCE:
This machine has been designed to give many years of trouble free service.
The only regular maintenance required is occasional de-scaling.
Descaling Procedure:
 Isolate machine from power supply.
 Isolate machine from water supply.
 ALLOW TO COOL COMPLETELY!
 Drain water from machine.
 Remove all lids.
 Remove as much scale as possible by hand, paying particular attention to level probes
(White plastic with steel tab). Be very careful not to damage any attachments.
 Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.
 Thoroughly clean and flush the machine before re-use.
 Follow installation and first time operation instructions.
1900052
Symptom
when machine first fills.
Water not heating
Machine not filling
Check water pressure , if this is OK then call
Check water pressure, if OK then call service
REV.3
Action required
service agent.
Call service agent
Call service agent
Call service agent
agent.
Page 9