The Back Light Is Not Working; Desoldering From El Terminal; Remove Screw For Lcd Cover - Seintek S2401 Service Manual

Scope meter
Table of Contents

Advertisement

7.5.

The back light is not working

When the back light is not working although the symbol is on the
screen.
To remove the Meter Case, refer to procedures chapter 2.5.1 to 2.5.3.
7.5.1.

Desoldering from EL terminal

7.5.2.

Remove screw for LCD cover

① Desoldering:
Desoldering EL terminal
(2 points).
② Rotate the PCB Assembly
180 degrees.
① Remove Screw:
Remove the five screw for
LCD cover. (5 Pcs)
② Rotate the PCB Assembly
180 degrees.