QTD
Series
1.0
Introduction
Overview
The intent of this manual is to provide information regarding general safety, installation, operation and
maintenance of this radiant tube heater. You must read and understand all instructions and safety
warnings before installing or servicing the radiant tube heater.
Heater Components
Prior to installation, verify that the heater's gas type and voltage (as listed on the rating plate) match
that of your application. Also verify that you have received all heater components included with your
radiant tube heater. Refer to page 44 for a list of the kit contents for your Series heater. Materials not
included in the heater kit contents (e.g., screws, vent material, terminals, etc.) are the responsibility of
the installer. Notify your product representative or Brant Radiant Heaters Limited of any discrepancy or
missing kit contents prior to installing unit.
Specifications
Chart 1.1
•
QTD Series Specifications
Model
Number
Gas Type
QTD-60N
Natural Gas
QTD-60P
Propane
QTD-80N
Natural Gas
QTD-80P
Propane
* Input at full rate.
** Recommended mounting heights are provided as a guideline. Actual conditions may dictate variations from
this data.
Shipping / Boxing:
B = Burner Control Box (15#) & (31.5"L x 17.5"W x 15.5"H)
T = Emitter Assembly and Reflector Box (88#) & (91"L x 31"W x 14"H)
NOTE: See Kit Contents on page 44.
1.0
Introduction
BTU/h
BTU/h
Low Fire*
High Fire*
40,000
60,000
40,000
60,000
50,000
80,000
50,000
80,000
3
•
Overview
•
Heater Components
Recommended
Mounting Heights**
Unit Weight
8 to 12 ft.
8 to 12 ft.
10 to 14 ft.
10 to 14 ft.
•
Specifications
Overall Unit
Length
103 lbs.
103"
103 lbs.
103"
103 lbs.
103"
103 lbs.
103"