Keylock Switch Problems Measurement Points Pictures Volume Up and Down Problems This document is Sony Ericsson confi dential and should be treated as confi dential in accordance Numeric Keyboard Problems MEASUREMENT POINTS with the agreement with Sony Ericsson. This document is intended for use by authorized service...
Info: More information about the equipment used for TRS can be found in the following location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf or matris.xls Note! The 0,64 mm Test Probes is recommended by Sony Ericsson when the DMM is used. – U Model Tab. See Picture 1.
Page 4
ABOUT Equipment List SEMC Troubleshooting Manual Aino - U10 SE Communication Interface SEPI BOX RF Test Cable Flexible Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf Location: CSPN – Repair Instructions – Mechanical – Tool Catalogue – RepairToolsCatalogue.pdf...
Page 5
ABOUT Equipment List SEMC Troubleshooting Manual Aino - U10 Customized Power Supply Channel 2 Cable (DCIO/SEPI) Step 4: Customize the cable according to the instructions below: Connect DCIO Cable and SEPI Interface Cable – A1 according to Picture 10. (Step 1, Step 2, Step 3 and Step 4)
Page 6
ABOUT Equipment List SEMC Troubleshooting Manual Aino - U10 Connection Instructions for the Dummy Battery This is the correct setup when the Dummy Battery is used. See Pictures 12 and 13. Picture 12 Picture 13 Test Cards Local SIM Any functional Local SIM Card Memory Card SanDisk microSD™...
TROUBLESHOOTING Dead Phone Problems SEMC Troubleshooting Manual Aino - U10 Dead Phone Problems part 1 Dead Phone Problems part 2 START START Step 1: Try to Recover the Phone by using EMMA SW: NOTE ! Update SEMCBOOT after this Run EMMA SUCR SW...
TROUBLESHOOTING Touch Display Problems - Opto Sensor Problems SEMC Troubleshooting Manual Aino - U10 Touch Display Problems Opto Sensor Problems START START Step 1: Replace PBA Top and retest the Phone If successful claim PBA Top if not go to step 2.
TROUBLESHOOTING Proximity Sensor Problems - On/Off Key Problems SEMC Troubleshooting Manual Aino - U10 Proximity Sensor Problems On/Off Key Problems START Step 1: START Replace PBA Top and retest the Phone If successful claim PBA Top if not go to step 2.
TROUBLESHOOTING Keylock Switch Problems - Volume Up and Down Problems SEMC Troubleshooting Manual Aino - U10 Keylock Switch Problems Volume Up and Down Problems START START Step 1: Step 1: Load ETS SW into the Phone Load ETS SW into the Phone...
TROUBLESHOOTING Flash LED Problems - Vibrator Problems SEMC Troubleshooting Manual Aino - U10 Flash LED Problems Vibrator Problems START START Step 1: Load ETS SW into the Phone Use TRS Fixture Step 1: Connect: VBATT and DCIO/SEPI Load ETS SW into the Phone...
TROUBLESHOOTING Camera Problems - Camera Auto Focus and Shutter Problems SEMC Troubleshooting Manual Aino - U10 Camera Problems Camera Auto Focus and Shutter Problems START Step 1: Replace Camera 8 Mpixel CMOS and retest the Phone START If successful claim Camera 8 Mpixel CMOS if not go to step 2.
TROUBLESHOOTING Charging Problems - USB Charging Problems SEMC Troubleshooting Manual Aino - U10 Charging Problems USB Charging Problems START Step 1: START Perform the System Connector Protection Test If successful go to step 2. Perform the System Connector Protection Test...
Hands-Free (PHF) Detection Problems TROUBLESHOOTING SEMC Troubleshooting Manual Hands-Free (PHF) Aux Microphone Problems Aino - U10 Hands-Free (PHF) Detection Problems Hands-Free (PHF) Aux Microphone Problems START NOTE ! START Before starting this TRS guide, make sure that the Hands-Free (PHF) Detection is working properly.
TROUBLESHOOTING Hands-Free (PHF) Aux Earphone Problems - Microphone Problems SEMC Troubleshooting Manual Aino - U10 Hands-Free (PHF) Aux Earphone Problems Microphone Problems START START NOTE ! Before starting this TRS guide, make sure that Hands-Free (PHF) Step 1: Detection is working properly.
TROUBLESHOOTING Earphone Problems - Loudspeaker Problems SEMC Troubleshooting Manual Aino - U10 Earphone Problems Loudspeaker Problems START START Load ETS SW into the Phone Load ETS SW into the Phone Use TRS Fixture and Connect: Use TRS Fixture and Connect: Slider FPC Assy, Display 3"...
TROUBLESHOOTING Data Communication Problems - FM Radio Problems SEMC Troubleshooting Manual Aino - U10 Data Communication Problems FM Radio Problems START Step 1: Perform the System Connector Protection Test START If successful go to step 2. Perform the System Connector Protection Test...
TROUBLESHOOTING Bluetooth Problems SEMC Troubleshooting Manual Aino - U10 Bluetooth Problems part 1 Bluetooth Problems part 2 START START Step 1: Load ETS SW into the Phone NOTE ! 1 Ohm between Use TRS Fixture Before starting this guide the Bluetooth Problems part 1...
TROUBLESHOOTING A-GPS Problems SEMC Troubleshooting Manual Aino - U10 A-GPS Problems part 1 A-GPS Problems part 2 START START Step 1: Replace Carrier Inner Assembly and retest the Phone NOTE ! If successful claim Carrier Inner Assembly Before starting this the A-GPS Problems part 1 TRS guide must be finished.
TROUBLESHOOTING WLAN Problems - Alert and Real Time Clock Problems SEMC Troubleshooting Manual Aino - U10 WLAN Problems Alert and Real Time Clock Problems START START NOTE ! Before starting this TRS guide, check if Bluetooth is working properly. Does...
TROUBLESHOOTING Accelerometer Problems - Slide Sensor Problems SEMC Troubleshooting Manual Aino - U10 Accelerometer Problems Slide Sensor Problems START START Step 1: Step 1: Load ETS SW into the Phone Replace Keyboard FPC Assembly and retest the Phone If successful claim Keyboard FPC Assembly if not go to step 2.
TROUBLESHOOTING SIM Problems - Memory Stick Problems SEMC Troubleshooting Manual Aino - U10 SIM Problems Memory Stick Problems START Step 1: START Load ETS SW into the Phone Use TRS Fixture Insert the Test SIM Card into X2402 Card Connector on the PBA...
TROUBLESHOOTING System Connector Protection Test - Backup Capacitor Test SEMC Troubleshooting Manual Aino - U10 System Connector Protection Test Backup Capacitor Test To perform this test use: Perform the Ohm measurements by using the DMM instrument (Fluke). Phone with the ETS SW Note! he Battery must be removed from the Phone during this test.
TROUBLESHOOTING ASIC Revision Test SEMC Troubleshooting Manual Aino - U10 ASIC Revision Test Note! The Key Test must be deactivated during this test. The purpose of this test is to verify: That the ASICs are correctly mounted, That communication is Ok, That the ASIC revisions are correct.
MEASUREMENT POINTS Keyboard FPC Assembly SEMC Troubleshooting Manual Aino - U10 Keyboard matrix S1000 S1001 S1002 S1003 KEYFLEX CONNECTOR X1000 k t f v i t y t i KEYOUT0 SOFT RIGHT KEYOUT1_1 S1004 S1005 S1006 S1007 KEYLOCK SWITCH B2B_TEST_KEKYBOARD...
APPENDIX Troubleshooting Fixture Setup Instructions SEMC Troubleshooting Manual Aino - U10 Troubleshooting Fixture Setup Instructions Top-part overview of the TRS Fixture, see picture 1. Connect Main Camera 8 MPixel CMOS to the X4300 BtB connector on the PBA according to picture 3.
Page 54
APPENDIX Troubleshooting Fixture Setup Instructions SEMC Troubleshooting Manual Aino - U10 Connect Slider FPC Assy, Display 3" TFT and PBA Top and place them into TRS Fixture Display Holder. Open the TRS Fixture according to picture 7. Secure them by using the locking screws according to picture 5.
Page 55
APPENDIX SEMC Troubleshooting Manual Aino - U10 Connect the Keyboard FPC Assembly to X2500 BtB connector and secure it by using the locking screws Close the TRS Fixture according to picture 9. according to picture 11. Picture 9 Picture 11...
Page 56
APPENDIX SEMC Troubleshooting Manual Aino - U10 Connect Power Supply Channel 1 (VBATT) Black and Red Lab Plugs to the TRS Fixture according to picture 13. Connect the RF Cable Flexible to the GPS RF Connector on the TRS Fixture according to picture 15.
Page 57
APPENDIX SEMC Troubleshooting Manual Aino - U10 The PIN marked with the GND text on the Top-part of the TRS Fixture can be used as an MP TRS Connect the RF Cable Flexible with RF Probe to the X1200 RF Switch according to picture 17.
Need help?