Durabrand T6609BK Service Manual page 48

14? color tv/vcr combination
Hide thumbs Also See for T6609BK:
Table of Contents

Advertisement

H.V./Power Supply CBA Top View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
1-10-13
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
R590
(H Adjustment)
TP503
+B
TP504
GND
VR601
+B ADJ
BT6600F01022-A

Advertisement

Table of Contents
loading

Related Products for Durabrand T6609BK

Table of Contents