Paloform ROBATA 72 CORTEN FIRE Installation Manual

Paloform ROBATA 72 CORTEN FIRE Installation Manual

Outdoor firepit

Advertisement

ROBATA 72 & 54 CORTEN FIRE |
OUTDOOR FIREPIT BURNER MODELS LIN-48, LIN-48P or LIN-36, LIN-36P
We recommend that our fire pits be
installed and serviced by professionals
that are certified in the U.S. by NFI
(National Fireplace Institute)
Installation Manual
Burner conforms to: ANSI Z21.97/CSA 2.41 - (2012/10/01) "Outdoor Decorative Gas Appliances"
DANGER - IF YOU SMELL GAS
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call your gas
supplier or fire department.
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance. An LP-cyllinder not connected for use shall not be
stored in the vicinity of this or any other appliance.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent,
car or home.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
WARNING: FOR OUTDOOR USE ONLY!
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference

Advertisement

Table of Contents
loading

Summary of Contents for Paloform ROBATA 72 CORTEN FIRE

  • Page 1 ROBATA 72 & 54 CORTEN FIRE | Installation Manual OUTDOOR FIREPIT BURNER MODELS LIN-48, LIN-48P or LIN-36, LIN-36P Burner conforms to: ANSI Z21.97/CSA 2.41 - (2012/10/01) “Outdoor Decorative Gas Appliances” DANGER - IF YOU SMELL GAS 1. Shut off gas to the appliance. 2.
  • Page 2: Safety Information

    SAFETY INFORMATION ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNINGS: WARNING: 10. Inspect the appliance before each use. Any modification to this appliance or its controls can be dangerous. 11. Turn the appliance off and let cool before servicing, installing, repairing or covering.
  • Page 3 POSITIONING GAS & ELECTRICAL SUPPLY ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual 4” 19” See page 12 of this manual for Gas Installation Requirements LOCATION OF BURNER This appliance requires 110V AC power supply in ROBATA 54 24” LIN-36 BURNER 8”...
  • Page 4: Placement And Assembly

    PLACEMENT AND ASSEMBLY ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual ATTENTION: Cor-Ten Steel is designed to rust in order to form a protective layer that resists further CAUTION: corrosion. This layer can take months to stabilize depending on climate and weather conditions. HEAVY: Use care Rust will bleed until it stabilizes.
  • Page 5 COMPONENTS ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual 4. Corten Cover 3. Burner Assembly (LIN-36 & 48) 5. Gas Connection 2. Media Tray 6. Power Connection 24 VAC 1. Body Suggested location for gas and electrical. RECOMMENDED: Outdoor receptacle with weatherproof “in-use”...
  • Page 6: Clearance To Combustibles

    CLEARANCE TO COMBUSTIBLES ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual 72” 72” 8” 8” FIG 3. MINIMUM CLEARANCES TO COMBUSTIBLES...
  • Page 7: Connecting To Gas Supply

    CONNECTING TO GAS SUPPLY ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNING: INSTALLATION REQUIREMENTS CHECKING GAS CONNECTION A qualified service person must Installation must include a manual shutoff valve, union, WARNING: Test all gas piping and connections connect the appliance to the gas and plugged 1/8”...
  • Page 8: Burner Assembly

    4. Fill the burner trough evenly with burner media (NG - crushed tempered glass; LP - volcanic rock). Do not use parts specifically approved for obstruct the pilot ignition port with burner media! Do not use media not supplied by Paloform! use with this appliance may result in property damage or personal injury.
  • Page 9 NOTES ABOUT COVERS ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNING: To avoid accidental ignition, always turn off gas and lock out power supply when covering fire pit. Robata includes two covers: a fabric, all-weather cover and a stainless steel insert which converts your fire pit into a table when not in use.
  • Page 10 LIGHTING YOUR FIRE PIT ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNINGS: INITIAL LIGHTING INSTRUCTIONS Failure to follow these instructions exactly may result in fire or explosion causing property damage, personal Before placing burner assembly into a housing: injury or loss of life.
  • Page 11 LIGHTING YOUR FIRE PIT ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNING: OPERATING INSTRUCTIONS This appliance is designed to be connected to a power 1. STOP! Read the safety information on pages 1, 2 and 7 of this source that is controllable by a switch.
  • Page 12: Technical Data

    TECHNICAL DATA ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual Burner Dimensions 48” (LIN-48), 36” (LIN-36) 9” 10” 8” Burner Specifications MODEL # MAX INPUT INLET INLET MANIFOLD ORIFICE SIZE BURNER PORTS PORT SIZE Btu/Hr PRESSURE MIN PRESSURE MAX PRESSURE LIN-36 60,000...
  • Page 13: Cleaning And Maintenance

    CLEANING AND MAINTENANCE ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNING: Turn off gas before servicing fire pit. It is recommended that a qualified service technician perform these check-ups at the beginning of each fire pit season. If any irregularities are apparent with operation, please refer to Troubleshooting guide, pages 13-14.
  • Page 14: Troubleshooting

    TROUBLESHOOTING ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNING: OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner shuts off/relights intermittently. Wind or gusts in excess of 16 km/h Protect pilot from wind with Turn off appliance and let cool before servicing.
  • Page 15 TROUBLESHOOTING cont’d ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual WARNING: OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When power is turned on, nothing No power to unit Check connections between Turn off appliance and let cool before servicing. Only a qualified service happens controls, power adapter and power source...
  • Page 16: Illustrated Parts List

    ILLUSTRATED PARTS LIST ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual KEY # DESCRIPTION LIN-72 LIN-72P Straight Burner w/ Venturi LB14V072 LB14V072 Throat Plate Set (two pieces) LB14001 LB14001 Burner Tray & Chassis LB14072 LB14072 Control Box c/w Cover CBLIN CBLIN Pilot Assembly...
  • Page 17 ILLUSTRATED PARTS LIST cont’d ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual...
  • Page 18: Wiring Diagram

    ILLUSTRATED PARTS LIST ROBATA 72/54 CORTEN FIRE | Owner and Installation Manual Wiring Diagram IGNITION CONTROL BOARD: CC-9120-30 PILOT: NA410 OR LP410 GAS VALVE: GVBGD258 AC POWER ADAPTER INPUT: AC 120V 60 Hz 8A OUTPUT: 24 VAC, 750 mA CHASSIS GROUND...
  • Page 19: Warranty Information

    SERIAL NO: by Paloform Inc. in the appliance are found to be defective in materials or workmanship, Paloform Inc. will, at its option, replace or repair the defective components at no charge to the original owner. Paloform Inc. will also pay...

This manual is also suitable for:

Robata 54 corten fireLin-48Lin-48pLin-36pLin-36

Table of Contents