DANGER - IF YOU SMELL GAS
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call your gas
supplier or fire department.
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance. An LP-cyllinder not connected for use shall not be stored in the
vicinity of this or any other appliance.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car
or home.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury
or property damage. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
WARNING: FOR OUTDOOR USE ONLY!
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference

Advertisement

Table of Contents
loading

Summary of Contents for Paloform Fold 48-E LP Corten

  • Page 1 FOLD 48 FIRE TABLE Electronic Ignition Installation + Owner's Manual Meets the essential requirements as described in the European Directive 2009/142/EC DANGER - IF YOU SMELL GAS 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.
  • Page 2: Safety Information

    SAFETY INFORMATION FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual WARNINGS: WARNING: 10. Do not use the appliance if any part has been under Any modification to this appliance or its IMPORTANT: This appliance should water. Immediately call a qualified service technician controls can be dangerous.
  • Page 3: Basic Assembly

    BASIC ASSEMBLY FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual UNPACK: Account for all parts (see p. 14) FRAGILE: Handle with care METAL COVER LEVEL: Place on a solid, level surface AIR VENTS: Do not block ventilation holes in base (see p.
  • Page 4: Dimensions And Specifications

    DIMENSIONS & SPECIFICATIONS FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual NATURAL GAS PROPANE Burner Model # CIR-E-18 CIR-E-18P Nominal Heat Input G20 - 20mbar: G31 - 37mbar: 25 kW 25 kW 1770 gr/h Burner Pressure 8.7 mbar 25 mbar Orifice Size...
  • Page 5: Required Clearances

    REQUIRED CLEARANCES FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual 1829 mm 72" 72” 6" 6” MINIMUM CLEARANCES TO COMBUSTIBLES...
  • Page 6 Do not obstruct the pilot lighting port with Do not remove the data plates burner media! Do not use any media not supplied by attached to the Outdoor Fire Pit the Paloform! Burner. These plates contain important information. 4. Follow the Initial Lighting Instructions on page 9.
  • Page 7 BURNER MEDIA & DECORATIVE TOPPING FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual METAL TABLE TOP DECORATIVE TOPPING MEDIA (VARIOUS): - FILL TOPPING TRAY - COVER BURNER MEDIA - KEEP BELOW LID LINE BURNER MEDIA: CRUSHED GLASS (NG) or LAVA ROCK (LP) - FILL BURNER MEDIA TRAY - COMPLETELY COVER BURNER RING VENTILATION GAP:...
  • Page 8: Connecting To Gas Supply

    CONNECTING TO GAS SUPPLY FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual WARNING: INSTALLATION REQUIREMENTS A qualified service person must connect This appliance must be installed and serviced by trained the appliance to the gas supply. Follow all CHECKING GAS CONNECTION gas installation and service technician only.
  • Page 9: Initial Lighting Instructions

    LIGHTING YOUR FIRE PIT FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual WARNINGS: INITIAL LIGHTING INSTRUCTIONS Failure to follow these instructions exactly may result in fire or explosion causing property damage, personal injury or loss Before placing burner assembly into a housing: of life.
  • Page 10 LIGHTING YOUR FIRE PIT FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual OPERATING INSTRUCTIONS WARNING: This appliance is designed to be connected to a power 1. STOP! Read the safety information on pages 1, 2 and 9 of this manual. source that is controllable by a switch.
  • Page 11: Cleaning And Maintenance

    CLEANING AND MAINTENANCE FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual KEEP YOUR FIRE PIT COVERED Covering your fire pit with its all-weather cover when not in use will prolong the life of PILOT ASSEMBLY all its components. WARNING: Turn off gas before servicing fire pit.
  • Page 12: Troubleshooting

    FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual TROUBLESHOOTING WARNING: OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Turn off appliance and let cool before Burner shuts off/relights intermittently. Wind or gusts in excess of 16 km/h Protect pilot from wind with servicing.
  • Page 13 TROUBLESHOOTING cont’d FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual WARNING: OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Turn off appliance and let cool before When power is turned on, nothing No power to unit Check connections between servicing.
  • Page 14: Illustrated Parts List

    Vessel (not shown) FOL48-(colour code) same WARNING: Failure to position parts in accordance with diagrams or failure to use parts specifically approved for this appliance may result in property damage or personal injury. REPLACEMENT PARTS ARE AVAILABLE FROM PALOFORM...
  • Page 15 FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual ILLUSTRATED PARTS LIST - cont’d Natural Gas Propane CIR Control Box Cover CIR-E-BOX same CIR Control Box Housing CIR-E-BOX same Dual Solenoid Valve E-VAL-BASO w/ LP reg. spring 3/8”x1-1/2”...
  • Page 16: Wiring Diagram

    FOLD 48 FIRE TABLE CE Electronic Ignition | Installation & Owner's Manual ILLUSTRATED PARTS LIST Wiring Diagram IGNITION CONTROL BOARD: E-BOARD-CC9 PILOT: PIL-E-410 OR PIL-E-410LP GAS VALVE: E-VAL-BASO AC POWER ADAPTER AC POWER ADAPTER INPUT: AC 230VAC 60Hz INPUT: AC 120V 60 Hz 8A OUTPUT: 24 VAC, 750 mA OUTPUT: 24 VAC 1 A 24 VA CHASSIS GROUND...
  • Page 17: Warranty Information

    After installation, if any of the components manufactured by Paloform in the appliance are found to be defective in materials or workmanship, Paloform will, at its option, replace or repair the defective components at no charge to the original owner.