Roland V-440HD Owner's Manual page 71

Multi-format video mixer
Hide thumbs Also See for V-440HD:
Table of Contents

Advertisement

* The following controls correspond to each Bank Select message.
--------------------------------------------------------------------------------------------
Bank Select
Program No.
MSB/LSB
--------------------------------------------------------------------------------------------
00H/00H
00H - 03H
--------------------------------------------------------------------------------------------
01H/00H
00H - 03H
--------------------------------------------------------------------------------------------
02H/00H
00H - 04H
-------------------------------------------------------------------------------------------
03H/00H
00H - 04H
--------------------------------------------------------------------------------------------
❍Modulation (controller number 1)
Status
2nd byte
BnH
01H
❍Breath-type (controller number 2)
Status
2nd byte
BnH
02H
❍Foot-type (controller number 4)
Status
2nd byte
BnH
04H
❍Portamento Time (controller number 5)
Status
2nd byte
BnH
05H
❍Volume (controller number 7)
Status
2nd byte
BnH
07H
❍Balance (controller number 8)
Status
2nd byte
BnH
08H
❍Panpot (controller number 10)
Status
2nd byte
BnH
0AH
❍Expression (controller number 11)
Status
2nd byte
BnH
0BH
❍Effect Control 1 (controller number 12)
Status
2nd byte
BnH
0CH
❍Effect Control 2 (controller number 13)
Status
2nd byte
BnH
0DH
❍General Purpose Controllers 1–4 (controller numbers 16-19)
Status
2nd byte
BnH
10H - 13H
❍Hold 1 (controller number 64)
Status
2nd byte
BnH
40H
❍Portamento (controller number 65)
Status
2nd byte
BnH
41H
❍Sostenuto (controller number 66)
Status
2nd byte
BnH
42H
❍Soft (controller number 67)
Status
2nd byte
BnH
43H
Control
A ch, INPUT 1-4
B ch, INPUT 1-4
C ch, INPUT AB-4
D ch, INPUT AB-4
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
xxH
3rd byte
xxH
3rd byte
xxH
3rd byte
xxH
❍Legato (controller number 68)
Status
2nd byte
BnH
44H
❍Hold 2 (controller number 69)
Status
2nd byte
BnH
45H
❍Sound Controllers 1–10 (controller numbers 70–79)
Status
2nd byte
BnH
46 - 4FH
❍General Purpose Controllers 5–8 (controller numbers 80–83)
Status
2nd byte
BnH
50 - 53FH
❍Portamento Control (controller number 84)
Status
2nd byte
BnH
54H
❍Effect Depth 2–5 (controller number 92–95)
Status
2nd byte
BnH
5C - 5FH
●Program Change
Status
2nd byte
CnH
ppH
pp= program number:00H - 7FH (prog.1 - prog.128)
* When you select channel A or channel B inputs, make memory settings, or specify how
sub-channels are mixed in Presentation mode, these messages will be transmitted in
conjunction with Bank Select messages. For details, refer to the section on Bank Select.
●Channel Pressure
Status
2nd byte
DnH
vvH
* Just as for Control Changes, the messages assigned in MIDI Setup will be transmitted
when you operate the panel. For the factory settings, refer to "Settings Transmitted/
Received Using MIDI" (p. 75).
●Pitch Bend Change
Status
2nd byte
EnH
llH
mm, ll= pitch bend value:00 00H - 40 00H - 7F 7FH (-8192 - 0 -+8191)
* Just as for Control Changes, the messages assigned in MIDI Setup will be transmitted
when you operate the panel. For the factory settings, refer to "Settings Transmitted/
Received Using MIDI" (p. 75).
●Data Set 1 (DT1)
This is the message that transfers actual data, and is used to specify data for a device.
Status
Data bytes
F0H
41H, dev, 00H, 00H, 10H, 12H,
aaH, bbH, ccH, ddH, ..., eeH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H–1FH, factory setting is 10H)
00H
1st byte of model ID (V-440HD)
00H
2nd byte of model ID (V-440HD)
10H
3rd byte of model ID (V-440HD)
12H
Command ID (DT1)
aaH
Upper byte of address
bbH
Address
ccH
Address
ddH
Data: the actual data to be transmitted. Multi-byte data is transmitted
in the order of the address.
:
:
eeH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* For details on setting the address, size, and checksum, refer to "Example of exclusive
message and checksum calculation".
* Data that exceeds 256 bytes must be divided into packets of 256 bytes or less for
transmission. If a subsequent "Data Set 1" message is transmitted, an interval of at least
20 ms must be left between packets.
MIDI implementation
3rd byte
xxH
3rd byte
xxH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
mmH
Status
F7H
71

Advertisement

Table of Contents
loading

Table of Contents