Acon On Call User Manual

Acon On Call User Manual

Advanced blood glucose monitoring system

Advertisement

ACON Laboratories, Inc.
10125 Mesa Rim Road,
San Diego, CA 92121, USA
30175 Hannover, Germany
Number: 1150589401
Effective date: 2010-xx-xx
EC REP
MDSS GmbH
Schiffgraben 41
2010 ACON Laboratories, Inc.
Blood
Glucose
Monitoring System
User's Manual
0197

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the On Call and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acon On Call

  • Page 1 Blood Glucose Monitoring System User's Manual ACON Laboratories, Inc. 10125 Mesa Rim Road, San Diego, CA 92121, USA EC REP MDSS GmbH Schiffgraben 41 30175 Hannover, Germany 0197 Number: 1150589401 2010 ACON Laboratories, Inc. Effective date: 2010-xx-xx...
  • Page 2 Blood Glucose Monitoring System Self monitoring of blood glucose (SMBG) is an integral part of diabetes care, but the high cost of testing can make this impossible. At ACON, our goal is to provide high quality glucose monitoring at a price that allows you to test as often as necessary.
  • Page 3: Table Of Contents

    Table of Contents Getting Started ..................1 Component Descriptions .............. 2 ® On Call Advanced Blood Glucose Meter ........3 Meter Display ................5 ® On Call Advanced Blood Glucose Test Strips ......6 ® On Call Advanced Glucose Control Solution ......9 Install the Battery ................
  • Page 4: Getting Started

    Advanced Blood Glucose Monitoring glucose concentration. ® System. Depending on the On Call Advanced product you purchase, 2. Test Strips: Strips with a chemical reagent system used with the some of the components may need to be purchased separately. Please meter to measure glucose concentration in blood.
  • Page 5: On Call Advanced Blood Glucose Meter

    Liquid Crystal Display (LCD): Shows your test results, and helps you On Call Advanced Blood Glucose Meter On Call Advanced Blood Glucose Meter ® ® through the testing process. M Button: Recalls previous test results from the meter memory and performs other menu selection functions.
  • Page 6: Meter Display

    (300 mg/dL), which suggests a ketone test is recommended. ® The On Call Advanced Blood Glucose Test Strips are thin strips with a Consult your healthcare professional about testing for ketones. chemical reagent which work with the On Call ®...
  • Page 7 90-140 390001 2009-01 • Tear the pouch carefully starting from the tear gap. Avoid damaging CTRL 2 ACON Laboratories, Inc. 4108 Sorrento Valley Boulevard, or bending the test strip. San Diego, CA 92121, USA 16.4-21.7 mmol/L EC REP 30 C...
  • Page 8: On Call Advanced Glucose Control Solution

    Do not swallow or inject. • Shake well before using. • Control solution tests are specified to be accurate only when The On Call Advanced Glucose Control Solution ® tested between 10 and 40 C. contains a known concentration of glucose. It is ®...
  • Page 9: Install The Battery

    Install the Battery Meter Setup Before Testing Before testing, the following steps should be followed: Battery may not be preinstalled in the meter. Two CR 2032 3.0V coin cell batteries are required. Please find the batteries in your carrying case and install them according to the following steps: Step 1 - Coding the Meter Step 1 - Coding the Meter 1.
  • Page 10 5. Meal Marker: The meter comes with the Meal Marker feature disabled. The meter shall allow the user to enable or disable the test result meal marker option. The words "On" or "Off" will be displayed on the large center segments of the display and the symbol of "before meal"...
  • Page 11 second Test Reminder. Press the M button to adjust the second selection. When the Hyper indicator is "Off", Test Reminder time. (Time is adjusted by every 15 minutes.) pressing the S button will go to the next Hypo Press the S button to confirm the second Test Reminder time indicator set up.
  • Page 12: Performing A Quality Control Test

    Control Solution • At least once a week. 35 C nonabsorbent surface. Touch the sample tip EC REP ACON Laboratories, Inc. 4108 Sorrento Valley Boulevard, Schiffgraben 41 MDSS GmbH San Diego, CA 92121, USA 30175 Hannover, Germany of the test strip to the control solution drop. If 1.
  • Page 13: Testing Your Blood

    DO NOT use the system to test blood, as the system may not be working properly. If you cannot fix the problem, contact your dealer for help. Please contact your dealer for information on ordering the On Call ® Advanced Glucose Control Solution Kit, which contains Control Solution...
  • Page 14 Adjustment: Fingertip Testing 1 and 2 for delicate skin for normal skin 4 and 5 for calloused or thick skin For fingertip sampling, adjust the depth penetration to reduce the Note: Greater pressure of the lancing device discomfort. You do not need the clear cap for fingertip sampling. against the finger will also increase the puncture depth.
  • Page 15 For the greatest reduction in pain, lance on 2. Choose a puncture site on the forearm or the sides of the fingertips. Rotation of sites is palm. Select a soft, fleshy area of the recommended. Repeated punctures in the forearm that is clean and dry, away from same spot can make your fingers sore and bone, and free of visible veins and hair.
  • Page 16: Step 2 - Testing Blood Glucose

    Step 2 - Testing Blood Glucose Step 2 - Testing Blood Glucose Lancet Precautions • Do not use the lancet if the safety tab is missing or loose when you take the lancet out of the bag. Note: Insertion of a new test strip at any time, except while in the •...
  • Page 17: Hi" And "Lo" Messages

    4. The meter will count down from 5 to 1 and 5. After inspection, record valid results in your logbook with the date then display the measurement results. The and time, and compare them to the target goals set by your meter will also beep to indicate that healthcare professional.
  • Page 18: Hypo" And "Hyper" Messages

    Peritoneal dialysis solutions containing icodextrin (e.g., Extraneal, from patients in a hyperosmolar state (with or without ketosis) have Icodial). ® not been tested and are not recommended for testing with On Call Certain types of intravenous immunoglobulin therapies (e.g., Advanced Blood Glucose Monitoring System. Octagam 5%).
  • Page 19: Using The Meter Memory

    Note: If you do not wish to view your average glucose Using the Meter Memory measurements, you can press the S button again to turn off the display. The meter automatically stores up to 300 test records. Each record 5. While in data average mode, press the M button to switch between includes the test result, time and date.
  • Page 20: Transferring Records

    3. The display will show "MEM" and "---", the 5. Once the data transfer is complete, the meter meter will clear its memory and turn itself off will display "End" and "PC" and turn itself off after a moment. after a moment. 4.
  • Page 21: Maintenance

    Blood Glucose Monitoring System Blood Glucose Monitoring System Blood Glucose Meter Your On Call Advanced Blood Glucose Meter does not require special ® maintenance or cleaning. A cloth dampened with water and a mild detergent solution can be used to wipe the outside of the meter.
  • Page 22: Suggested Testing Times And Target Goals

    Target Goals and Laboratory Results ® Your On Call Advanced Blood Glucose System and laboratory results Tracking your blood glucose concentration through frequent testing is both report the glucose concentration in the serum or plasma an important part of proper diabetes care. Your diabetes health care component of your blood.
  • Page 23: Troubleshooting Guide

    Call Advanced brand of test strip ® code chip inserted in the If the problem persists, contact your with the On Call Advanced Blood ® meter local distributor. Glucose Meter. If the problem persists, contact your local...
  • Page 24: Specifications

    Specifications Warranty Please complete the warranty card that came with this product and mail Feature Specification it to your dealer to register your purchase. If the meter fails to work for any reason other than obvious abuse within Measurement Range 0.6-33.3 mmol/L (10 - 600 mg/dL) the first five (5) years from purchase, we will replace it with a new meter free of charge.
  • Page 25: Index

    Index Averaging Results....31 S Button........3 Set the Clock......12 Battery, Replacing the.....35 Specifications......41 Carrying Case......1 Strip ejector......3, 28 Clearing the Memory....32 Procedure Data Port.......3, 33 Precautions and Limitations..29 Date Format......8, 10 Testing Y our Blood....20 Guidelines........i Quality Control Test....17 Hematocrit......30, 41 Control Solution......9 Hyperglycemia....14, 29 How to Run.......17...

This manual is also suitable for:

On call advanced

Table of Contents