4. Checking Component Video Output R-Y

<Purpose>
This checks component video output R-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bars
COMPONENT VIDEO OUT (R-Y)
Test point
connector (75 Ω terminated)
Instrument
Oscilloscope
Specification
700 ± 50 mVp-p
Checking method:
1) Confirm that the R-Y level is 700 ± 50 mVp-p.
Figure 7-4
5. Component Video Output Y Level Adjustment
(VP-52 BOARD)
<Purpose>
This adjustments component video output Y. If it is incorrect,
correct brightness will not be attained when connected to, for in-
stance, projector.
Mode
Video level adjustment in test mode
Signal
Color bars
COMPONENT VIDEO OUT (Y)
Test point
connector (75 Ω terminated)
Instrument
Oscilloscope
Adjusting element
RV101
Specification
1.00
Adjusting method:
1) In the test mode initial menu "6" Video Level Adjustment, set
so that color bars are generated.
2) Adjust the RV101 to attain 1.00
Figure 7-5
700 ± 50 mVp-p
+ 0.04
Vp-p
– 0.02
+ 0.04
Vp-p
– 0.02
+ 0.04
1.00
– 0.02

6. Progressive Video Output Level Adjustment

(VP-52 BOARD)
<Purpose>
This adjustments progressive video output. If it is incorrect, cor-
rect brightness will not be attained when connected to, for instance,
projector.
Mode
Signal
Test point
Instrument
Adjusting element
Specification
Adjusting method:
1) In the test mode initial menu "7" Prog Level Adjustment, set
so that color bars are generated.
2) Adjust the RV401 to attain 1.00
7. Checking RGB Output R (AEP, UK Model)
<Purpose>
This checks RGB output R. If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
Signal
Test point
Instrument
Specification
Checking method:
1) Confirm that the R level is 700 ± 50 mVp-p.
Vp-p
7-3
Video level adjustment in test mode
Color bars
COMPONENT VIDEO OUT (Y)
connector (75 Ω terminated)
Oscilloscope
RV401
+ 0.04
1.00
Vp-p
– 0.02
+ 0.04
Vp-p
– 0.02
1.00
Figure 7-6
In test mode,
[0]
Push
for Syscon Diagnosis and
[8]
[8]
push
for Video and push
[ENTER]
for Euro TV Check and
[NEXT]
push
twice for RGB out
Color bars
EURO AV 1 (RGB)-TV connector
pin qg (75 Ω terminated)
Oscilloscope
700 ± 50 mVp-p
700 ± 50 mVp-p
Figure 7-7
+ 0.04
Vp-p
– 0.02
and