Technical Services Training Group
N200 COBBA faulty
Check 13MHz IF at N700, pin 23, 24 – if the generator level (-80dBm....-105dBm) is changing - amplitude of IF must also change
Check RXC signal at N700, pin 36 – if the generator level is changed – the amplitude of signal must also change
Check R725 if these signals are not measurable or too low in amplitude – see diagram below
Check VBB 2.8VDC at C117 (near CCONT)
Check VCOBBA 2.8VDC at C248 (near COBBA)
Check COBBACLK at J201: 3.6Vpp – see diagram below
If all signals and voltages are ok – set the phone in call mode with CMU/CMD
Check the RX/TX values while knocking (with a nonmetallic item) around COBBA
If any error appears – probably broken solderings under COBBA - change N200 if possible (if not underfilled)
If the errors persist after rework of COBBA – MAD or PCB might be the reason
NOTE:
If COBBA or MAD is underfilled – swap the phone, because these components are not changeable!
If COBBA was changed - SIMlock and IMEI entries must be rewritten with NOKIA Security Password, if this
procedure is permitted to you!