Assembly - Standard Ceiling Mount
1
Preparation for standard mounting
Remove the slide-on mounting bracket (A) from the canopy
(C) by loosening the four screws (SS) on the the top of the
canopy (C).
Remove the two non-slotted screws (SS) and loosen the
slotted screws (SS). This will enable you to remove the
slide-on mounting bracket (A).
SS
3
Assembling the fan
WARNING: Failure to properly install the locking pin (DD)
could result in the fan becoming loose and possibly
falling.
Loosen, but do not remove, the setscrews (HH) on the collar
on top of the fan-motor assembly (D).
Align the holes at the bottom of the ball/downrod assembly
(B) with the holes in the collar on top of the fan-motor
assembly (D).
Carefully inset the hanger pin (CC) through the holes in the
collar and ball/downrod assembly (B). Be careful not to
jam the hanger pin (CC) against the wiring inside the ball/
downrod assembly (B).
Insert the locking pin (DD) through the hole near the end of
the hanger pin (CC) until it snaps into its locked position.
Re-tighten the setscrews (HH) on the collar on top of the
fan-motor assembly (D).
2
Routing the wires
Make sure the slot openings are on top and route the
wires existing at the top of the fan-motor assembly (D)
through the canopy (C) and then through the ball/down-
rod assembly (B).
A
C
CC
7
Please contact 1-877-527-0313 for further assistance.
C
B
D
C
B
DD
HH
D
HAMPTONBAY.COM