p
s
roduCt
peCifiCatioNs
gmVC95 a
d
irflow
ata
C
s
ooliNg
peeds
GMVC950453BX
High Stage
Tap
Adjust
CFM*
Minus(-)
540
A
Normal
600
Plus (+)
660
Minus(-)
720
B
Normal
800
Plus (+)
880
Minus(-)
900
C
Normal
1000
Plus (+)
1100
Minus(-)
1080
D
Normal
1200
Plus (+)
1320
GMVC950905CX
High Stage
Tap
Adjust
CFM*
Minus(-)
729
A
Normal
810
Plus (+)
891
Minus(-)
990
B
Normal
1100
Plus (+)
1210
Minus(-)
1323
C
Normal
1470
Plus (+)
1617
Minus(-)
1629
D
Normal
1810
Plus (+)
1991
GMVC951155DX
High Stage
Tap
Adjust
CFM*
Minus(-)
720
A
Normal
800
Plus (+)
880
Minus(-)
990
B
Normal
1100
Plus (+)
1210
Minus(-)
1260
C
Normal
1400
Plus (+)
1540
Minus(-)
1620
D
Normal
1800
Plus (+)
1980
* @ .1" - .8" w.c. ESP
Notes:
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Do not operate above .5" w.c. ESP in heating mode. Operating CFM between .5" and .8" w.c. is tabulated for cooling purposes only.
6
Low Stage
Tap
Adjust
CFM*
Minus(-)
351
A
Normal
390
Plus (+)
429
Minus(-)
468
B
Normal
520
Plus (+)
572
Minus(-)
585
C
Normal
650
Plus (+)
715
Minus(-)
702
D
Normal
780
Plus (+)
858
Low Stage
Tap
Adjust
CFM*
Minus(-)
495
A
Normal
550
Plus (+)
605
Minus(-)
693
B
Normal
770
Plus (+)
847
Minus(-)
900
C
Normal
1000
Plus (+)
1100
Minus(-)
1125
D
Normal
1250
Plus (+)
1375
Low Stage
Tap
Adjust
CFM*
Minus(-)
468
A
Normal
520
Plus (+)
572
Minus(-)
644
B
Normal
715
Plus (+)
787
Minus(-)
819
C
Normal
910
Plus (+)
1001
Minus(-)
1053
D
Normal
1170
Plus (+)
1287
www.goodmanmfg.com
GMVC950704CX
High Stage
Tap
Adjust
CFM*
Minus(-)
540
A
Normal
600
Plus (+)
660
Minus(-)
720
B
Normal
800
Plus (+)
880
Minus(-)
990
C
Normal
1100
Plus (+)
1210
Minus(-)
1286
D
Normal
1429
Plus (+)
1572
GMVC950905DX
High Stage
Tap
Adjust
CFM*
Minus(-)
720
A
Normal
800
Plus (+)
880
Minus(-)
900
B
Normal
1000
Plus (+)
1100
Minus(-)
1260
C
Normal
1400
Plus (+)
1540
Minus(-)
1620
D
Normal
1800
Plus (+)
1980
Low Stage
Tap
Adjust
CFM*
Minus(-)
351
A
Normal
390
Plus (+)
429
Minus(-)
468
B
Normal
520
Plus (+)
572
Minus(-)
644
C
Normal
715
Plus (+)
787
Minus(-)
836
D
Normal
929
Plus (+)
1022
Low Stage
Tap
Adjust
CFM*
Minus(-)
468
A
Normal
520
Plus (+)
572
Minus(-)
644
B
Normal
715
Plus (+)
787
Minus(-)
819
C
Normal
910
Plus (+)
1001
Minus(-)
1053
D
Normal
1170
Plus (+)
1287
SS-GMVC95