COMPRESSOR COMPONENTS

H
Part
Description
A
Pressure Switch - When the compressor is turned ON, this switch will shut compressor off automatically when tank pressure
reaches maximum shut-off / cut-out pressure. If compressor remains on and air is depleted from tank, this switch will allow
compressor to automatically restart at the restart / cut-in pressure.
B
ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
C
Discharge Tube - This tube carries compressed air from the pump to the check valve. This tube becomes very hot during use.
To avoid the risk of severe burns, never touch the discharge tube.
D
Check Valve - One-way valve that allows air to enter the tank, but prevents air in the tank from flowing back into the
compressor pump.
E
Belt Guard - Covers the belt, motor pulley, and flywheel.
F
Drain Valve - Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.
G
Tank Pressure Gauge - Indicates the amount of air pressure stored in the tank.
H
Air Filter - Keeps large particulates out of the air flowing into the compressor.
I
Tank Outlet / Discharge Port - Air delivery port for transfer of compressed air.