Installation - Electrical (continued)
2
Preparing the pressure switch
□ Remove the pressure switch cover by loosening the
screw (1), as shown. Use a Phillips screwdriver.
□ Set the cover aside until wiring is completed.
□ Familiarize yourself with these internal components of the
pressure switch.
□ Refer to the illustration below to identify the motor terminal
(2), line terminal (3), ground screw (4), and ground line (5).
3
Making the electrical connections
□ Remove the ground screw (1). Install the strain relief on the
pressure switch (2). Do not tighten the strain relief on the
power cord until wiring is complete. Insert the bare wires
[black, white, bare/green](3, 4, 5) through the strain relief.
□ Attach the bare/green ground wire (5) fi rst to the ground
screw (1) on the pressure switch body.
□ Look for the "Line" markings on the pressure switch. Install
the line wires (3, 4) and tighten the terminal screws (6).
3
6
1
14
1
2
4
6
4
3
2
5
5