Installation/Visual Inspection Checklist - Manitowoc Q450 Service Technician's Handbook

Q series ice machines
Hide thumbs Also See for Q450:
Table of Contents

Advertisement

4. Compare the results of step 3 with step 2. Ice
production checks that are within 10% of the chart
are considered normal. This is due to variances in
water and air temperature. Actual temperatures will
seldom match the chart exactly. If they match
closely, determine if:
• Another ice machine is required.
• More storage capacity is required.
• Relocating the existing equipment to lower the load
conditions is required.
Contact the local Manitowoc Distributor for information
on available options and accessories.

Installation/Visual Inspection Checklist

Possible Problem List
• Corrective Action List
Ice machine is not level
• Level the ice machine
Condenser is dirty
• Clean the condenser
Water filtration is plugged (if used)
• Install a new water filter
Water drains are not run separately and/or are not
vented
• Run and vent drains according to the Installation
Manual
Line set is improperly installed
• Reinstall according to the Installation Manual
–73–