Refrigeration Diagnostics; Before Beginning Service; Installation/Visual Inspection Checklist - Manitowoc CNF0201 Technician's Handbook

Countertop nugget ice machines
Table of Contents

Advertisement

Refrigeration Diagnostics

BEFORE BEGINNING SERVICE

Ice machines may experience operational problems
only during certain times of the day or night. A machine
may function properly while it is being serviced, but
malfunctions later. Information provided by the user can
help the technician start in the right direction, and may be
a determining factor in the final diagnosis.
Ask these questions before beginning service:
When does the ice machine malfunction? (night, day,
all the time, only during the Freeze cycle, etc.)
When do you notice low ice production? (one day a
week, every day, on weekends, etc.)
Can you describe exactly what the ice machine seems
to be doing?
Has anyone been working on the ice machine?
During "store shutdown," is the circuit breaker, water
supply or air temperature altered?
Is there any reason why incoming water pressure
might rise or drop substantially?

INSTALLATION/VISUAL INSPECTION CHECKLIST

Possible Problem List
Filter and/or condenser is dirty. Clean the filter and condenser.
Water filtration is plugged (if
used).
Water drain is not vented or is
improperly installed.
Part Number 000015432 Rev02 5/21
Corrective Action List
Install a new water filter.
Run and vent drains according
to the installation manual.