Bradford White PDX1-40S6FBN Installation And Operating Instruction Manual page 48

Powered direct vent gas water heater
Table of Contents

Advertisement

Maintenance continued-
5. Annually remove the inner door and main burner assembly to clean orifices
and related parts of any dirt or other foreign material. Inspect the burner
ports for obstructions or debris and clean with a wire brush as needed.
Wire brush and/or vacuum clean the combustion chamber as needed to
remove scale deposits and debris. NOTE: It is imperative for proper
operation of the water heater that the inner door be replaced in the original
location.
Do not operate water heater with jumpered, altered,
loosely tightened or absent controls and/or components.
Do not operate water heater with replacement controls
and/or components which are not exact duplicates of
original equipment.
Thoroughly inspect and replace, (as needed) burner inner
door gasket and/or sight window gasket any time burner
inner door is removed or disturbed.
Replace water heater if involved in flammable vapor
incident.
This water heater is equipped with a flammable vapor
sensor. If the sensor is exposed to flammable vapor, the
water heater control will shut down the water heater and
display a code of 7 flashes and then a 3 second pause.
If a 7 flash error code is present, check to see if flammable
vapor is present in the area. If flammable vapor is
present or suspected in the area, immediately leave the
area and contact a service professional.
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
If you are certain there is no flammable vapor present,
check the flammable vapor sensor to make certain
it has not become disconnected from the control.
Review this instruction manual for troubleshooting.