Resistance Specification Of Sensor - Kenmore 795.78773.801 Service Manual

Table of Contents

Advertisement

9-3 RESISTANCE SPECIFICATION OF SENSOR

TEMPERATURE
- 20 ˚C
- 15 ˚C
- 10 ˚C
- 5 ˚C
0 ˚C
+ 5 ˚C
+ 10 ˚C
+ 15 ˚C
+ 20 ˚C
+ 25 ˚C
+ 30 ˚C
+ 40 ˚C
+ 50 ˚C
• The resistance of the SENSOR has a ±5% tolerance.
• Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
RESISTANCE OF FREEZER/ICING
SENSOR
22.3 KΩ
16.9 KΩ
13.0 KΩ
10.1 KΩ
7.8 KΩ
6.2 KΩ
4.9 KΩ
3.9 KΩ
3.1 KΩ
2.5 KΩ
2.0 KΩ
1.4 KΩ
0.8 KΩ
- 78 -
RESISTANCE OF REFRIGERATOR &
DEFROST SENSOR & ROOM SENSOR
77 KΩ
60 KΩ
47.3 KΩ
38.4 KΩ
30 KΩ
24.1 KΩ
19.5 KΩ
15.9 KΩ
13 KΩ
11 KΩ
8.9 KΩ
6.2 KΩ
4.3 KΩ

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.78789.801795.78779.801795.78783.801

Table of Contents