continuously, it will turn in the Cooling air protective system in the Extra-LOW or stop
the fan motor.
The indoor fan motor is only controlled by the signal of indoor pipe coil
temperature, no matter the compressor turn ON/OFF, even the appliance turn in Heat
mode at first time.
4.4.4 The indoor fan motor will operate according to the different setting(High,
Median, Low and Automatic) by the remote control, but the anti-cold air system is
prior.
When the appliance run in the Heat mode with the Automatic setting at first time, the fan
speed will be in the LOW setting, and the operation diagram is shown as following
When the difference between the setting temperature and the room temperature equal to 2℃
or 4℃, the indoor fan speed will keep in current speed.
4.4.5 Overheating protection control
When overloading occurs during the heating operation, this system controls the
outdoor fan motor and compressor according to the indoor coil pipe temperature to
prevent the overloading of the compressor and restrict the pipe pressure to rise
up. When the indoor pipe temperature exceeds 53℃, the outdoor fan motor will be
turned OFF, and when the indoor pipe temperature falls below 49℃, the outdoor fan
motor recovers to ON; When the indoor pipe temperature exceeds 63℃, the appliance
will be turned OFF with 4 beeps of buzzer and cannot recover automatically. At the
same time, the error code, "E2", display.
4.4.6 Air flow direction control
The horizontal louver is controlled by a step motor, press the SWING button to swing or stop
the louver.
During the louver run in normal operation, the current position will be stored. When the
appliance turn off and louver swing automatically to the default position, it will position at the
stored position plus 5º.
4.5 The smart control
When the appliance operates at the smart, the air flow direction can be adjusted.
(1) H/C appliance
a. When the setting temperature is 26℃, the appliance will be ran in the Cool
if the room temperature exceeds 26℃.
O
D
E
O
D
E
Low
The setting temperature -2℃
MEDIAN
The setting temperature -4℃
High
17